Differences in encapsulating lead tissue in patients who underwent transvenous lead removal

被引:35
作者
Kolodzinska, Agnieszka [1 ]
Kutarski, Andrzej [2 ]
Koperski, Lukasz [3 ]
Grabowski, Marcin [1 ]
Malecka, Barbara [4 ]
Opolski, Grzegorz [1 ]
机构
[1] Med Univ Warsaw, Dept Cardiol, PL-02097 Warsaw, Poland
[2] Med Univ Lublin, Dept Cardiol, PL-20954 Lublin, Poland
[3] Med Univ Warsaw, Dept Pathol, PL-02097 Warsaw, Poland
[4] Jagiellonian Univ Cracow, Dept Electrocardiol, PL-31202 Krakow, Poland
来源
EUROPACE | 2012年 / 14卷 / 07期
关键词
Encapsulating lead tissue; Fibrocollagenous sheath; Lead removal; Silicone-insulated leads abrasion; Infective endocarditis; POLYETHER POLYURETHANES; PACEMAKERS; ELECTRODE; BIOMATERIALS; RECOGNITION; INFECTIONS; MYOCARDIUM; MANAGEMENT; THROMBOSIS; STENOSIS;
D O I
10.1093/europace/eur384
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
The aim of our study was to characterize specific tissue reaction of encapsulating lead tissue in patients who underwent transvenous lead removal and evaluate condition of the outer leads insulation. Fifty-six leads (27 atrial, 24 ventricular, 5 implantable cardioverter-defibrillators) were removed from 31 patients (mean age 70 years). Indications for removal were chronic pocket infection (CPI) (9 patients ), infective endocarditis (IE) (6), and non-infective indications (NI) (16). Leads with their surrounding tissue were fixed in paraformaldehyde. Tissues were embedded in paraffin wax, stained with haematoxylineosin, and examined histologically. The outer leads insulations were examined in stereomicroscope. The mean lead age encapsulated by connective tissue sheath was 89, whereas encapsulated by granulation tissue was 47.34 months (P 0.03). Calcification was present in 13 patients. Haemosiderine was observed only in patients with severe abrasion with perforation in the pocket (P 0.04). Vasculogenesis was present in one (6) with NI, five (56) with CPI, and three (50) with IE (P 0.02) and was associated with elevated white blood cells (WBC) (P 0.04). Eosinophilia was associated with elevated WBC (P 0.04). The most frequently observed are third level of degradation (severe with perforation) in the intracardiac part of the silicone leads. Insulation damage due to environmental stress cracking concerned all leads with polyurethane overlay. Granulation in encapsulating tissue was present in patients with younger leads. Vasculogenesis was observed more often in IE and CPI patients, which might indirectly indicate thickness of the sheath. Eosinophila may indicate allergic component of inflammation. Insulation damage frequently concerned the intracardiac part.
引用
收藏
页码:994 / 1001
页数:8
相关论文
共 51 条
[1]
PACEMAKER CONTACT SENSITIVITY - CLINICAL RECOGNITION AND MANAGEMENT [J].
ABDALLAH, HI ;
BALSARA, RK ;
ORIORDAN, AC .
ANNALS OF THORACIC SURGERY, 1994, 57 (04) :1017-1018
[2]
ANDERSON JM, 1992, BIODEGRADABLE POLYM, P122
[3]
Update on Cardiovascular Implantable Electronic Device Infections and Their Management A Scientific Statement From the American Heart Association [J].
Baddour, Larry M. ;
Epstein, Andrew E. ;
Erickson, Christopher C. ;
Knight, Bradley P. ;
Levison, Matthew E. ;
Lockhart, Peter B. ;
Masoudi, Frederick A. ;
Okum, Eric J. ;
Wilson, Walter R. ;
Beerman, Lee B. ;
Bolger, Ann F. ;
Estes, N. A. Mark, III ;
Gewitz, Michael ;
Newburger, Jane W. ;
Schron, Eleanor B. ;
Taubert, Kathryn A. .
CIRCULATION, 2010, 121 (03) :458-477
[4]
SURFACE THROMBOSIS AND FIBROUS ENCAPSULATION OF INTRAVENOUS PACEMAKER CATHETER ELECTRODE [J].
BECKER, AE ;
BECKER, MJ ;
EDWARDS, JE ;
CLAUDON, DG .
CIRCULATION, 1972, 46 (02) :409-&
[5]
Beyersdorf F, 1998, PACING CLIN ELECTROP, V11, P10753
[6]
Pacemaker and implantable cardioverter defibrillator infections [J].
Camus, C. ;
Donal, E. ;
Bodi, S. ;
Tattevin, P. .
MEDECINE ET MALADIES INFECTIEUSES, 2010, 40 (08) :429-439
[7]
Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads [J].
Candinas, R ;
Duru, F ;
Schneider, J ;
Lüscher, TF ;
Stokes, K .
MAYO CLINIC PROCEEDINGS, 1999, 74 (02) :120-125
[8]
MORPHOLOGICAL-CHANGES IN HUMAN MYOCARDIUM DURING PERMANENT PACING [J].
CHATELAIN, P ;
ADAMEC, R ;
COX, JN .
VIRCHOWS ARCHIV A-PATHOLOGICAL ANATOMY AND HISTOPATHOLOGY, 1985, 407 (01) :43-57
[9]
Chester MK, 2010, ST JUDE MED IMPORTAN
[10]
Diagnosis and management of infections involving implantable electrophysiologic cardiac devices [J].
Chua, JD ;
Wilkoff, BL ;
Lee, I ;
Juratli, N ;
Longworth, DL ;
Gordon, SM .
ANNALS OF INTERNAL MEDICINE, 2000, 133 (08) :604-608