Automatic recognition of vertebral landmarks in fluoroscopic sequences for analysis of intervertebral kinematics

被引:30
作者
Bifulco, P [1 ]
Cesarelli, M
Allen, R
Sansone, M
Bracale, M
机构
[1] Univ Naples Federico II, Dept Elect & Telecommun Engn, Biomed Engn Unit, Naples, Italy
[2] Univ Southampton, Inst Sound & Vibrat Res, Southampton SO9 5NH, Hants, England
关键词
intervertebral kinematics; vertebral segments; motion analysis; fluoroscopy; time-varying image processing;
D O I
10.1007/BF02345268
中图分类号
TP39 [计算机的应用];
学科分类号
081203 [计算机应用技术]; 0835 [软件工程];
摘要
Intervertebral kinematics closely relates to the functionality of the spinal segments, Direct measurement of the intervertebral kinematics in vivo is very problematic. The use of a fluoroscopic device can provide continuous screening of the lumbar tract during patient spontaneous motion, with an acceptable, low X-ray dose. The kinematic analysis is intended to be limited to planar motion, Kinematic parameters are computed from vertebral landmarks on each frame of the image sequence. Landmarks are normally selected manually in spite of the fact that this is subjective, tedious to perform and regarded as one of the major contributors to errors in the computed kinematic parameters. The aim of this work is to present an innovative method for the automatic recognition of vertebral landmarks throughout a fluoroscopic image sequence to provide an objective and more precise quantification of intervertebral kinematics. The recognition procedure is based upon comparing vertebral features in two adjacent frames by means of a cross-correlation index, which is also robust despite the low signal-to-noise ratio of the lumbar fluoroscopic images. To provide a quantitative assessment of this method a calibration model was used which consisted of two lumbar vertebrae linked by a universal joint. The reliability and accuracy of the kinematic measurements have been investigated. The errors are of the order of a millimetre for the localisation of the intervertebral centre of rotation and tenths of a degree for the intervertebral angle. Error analysis suggests that this method improves the accuracy of the intervertebral kinematic calculations and has the potential to automate the selection of anatomical landmarks.
引用
收藏
页码:65 / 75
页数:11
相关论文
共 50 条
[1]
INSTANTANEOUS AXES OF ROTATION OF THE TYPICAL CERVICAL MOTION SEGMENTS - A STUDY IN NORMAL VOLUNTEERS [J].
AMEVO, B ;
WORTH, D ;
BOGDUK, N .
CLINICAL BIOMECHANICS, 1991, 6 (02) :111-117
[2]
AMEVO B, 1991, THESIS U NEWCASTLE N
[3]
AN HS, 1996, P 11 ANN C N AM SPIN
[4]
Three-dimensional measurement of wedged scoliotic vertebrae and intervertebral disks [J].
Aubin C.-E. ;
Dansereau J. ;
Petit Y. ;
Parent F. ;
De Guise J.A. ;
Labelle H. .
European Spine Journal, 1998, 7 (1) :59-65
[5]
BAKKE SN, 1931, ACTA RADIOL S, P123
[6]
BIFULCO P, P WORLD C MED PHYS B, P97
[7]
BIFULCO P, 1998, THESIS U NAPLES ITAL
[8]
BIFULCO P, 1995, P BIOMED 95 SIM BIOM
[9]
Bogduk N, 1995, Proc Inst Mech Eng H, V209, P177, DOI 10.1243/PIME_PROC_1995_209_341_02
[10]
SPINE KINEMATICS - A DIGITAL VIDEOFLUOROSCOPIC TECHNIQUE [J].
BREEN, AC ;
ALLEN, R ;
MORRIS, A .
JOURNAL OF BIOMEDICAL ENGINEERING, 1989, 11 (03) :224-228