Rehydration improves the ductility of dry bone allografts

被引:10
作者
Erivan, Roger [1 ]
Villatte, Guillaume [1 ]
Cueff, Regis [1 ]
Boisgard, Stephane [1 ]
Descamps, Stephane [1 ]
机构
[1] Univ Clermont Auvergne, CHU Clermont Ferrand, CNRS, SIGMA Clermont,ICCF, F-63000 Clermont Ferrand, France
关键词
Allograft; Bone loss; Bone substitutes; Mechanical properties; Remoistened bone; Frozen bone; Young's modulus; Bone; GRAFT DONOR SITE; ILIAC CREST; MECHANICAL-PROPERTIES; COMPLICATIONS; FRACTURE;
D O I
10.1007/s10561-017-9630-9
中图分类号
Q2 [细胞生物学];
学科分类号
071013 [干细胞生物学];
摘要
Processing of bone allografts improves infectious safety and allows storing bone substitutes at room temperature. The aim of this study was to compare mechanical properties of the processed Osteopure (TM) bone with fresh frozen bone. All the samples were pieces from femoral heads retrieved during hip arthroplasty operations. The processing includes chemical decellularization, drying and irradiation with 25 kGy. Three types of samples were tested: 1. fresh frozen thawed wet, 2. dry non-rehydrated graft 3. dry rehydrated graft. In the 3-point bending test Young's modulus and stress at break yielded no significant difference among the 3 different sample groups. Rehydrating of the dry graft showed increased ductility in strain at break test compared with the other 2 groups (p = 0.003). In compression tests dry grafts had significantly higher maximum effective stress and apparent maximum deformation compared with the grafts of other groups (p < 0.05). Processed bone has almost similar mechanical properties compared with fresh frozen bone. However, rehydration of processed dry graft increases its ductility. These grafts may tolerate bending forces better before breakage.
引用
收藏
页码:307 / 312
页数:6
相关论文
共 14 条
[1]
[Anonymous], 2012, J MECH BEHAV BIOMED, V5, P231
[2]
MECHANICAL PROPERTY DISTRIBUTIONS IN THE CANCELLOUS BONE OF THE HUMAN PROXIMAL FEMUR [J].
BROWN, TD ;
FERGUSON, AB .
ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (03) :429-437
[3]
PELVIC INSTABILITY - CONSEQUENCE OF REMOVING ILIAC BONE FOR GRAFTING [J].
COVENTRY, MB ;
TAPPER, EM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1972, A 54 (01) :83-&
[4]
Effects of ionizing radiation on the mechanical properties of human bone [J].
Currey, JD ;
Foreman, J ;
Laketic, I ;
Mitchell, J ;
Pegg, DE ;
Reilly, GC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (01) :111-117
[5]
Goulet JA, 1997, CLIN ORTHOP RELAT R, P76
[6]
GUHA SC, 1983, BRIT J PLAST SURG, V36, P305
[7]
Persistent iliac crest donor site pain: Independent outcome assessment [J].
Heary, RF ;
Schlenk, RP ;
Sacchieri, TA ;
Barone, D ;
Brotea, C .
NEUROSURGERY, 2002, 50 (03) :510-516
[8]
HARVESTING AUTOGENOUS ILIAC BONE-GRAFTS - A REVIEW OF COMPLICATIONS AND TECHNIQUES [J].
KURZ, LT ;
GARFIN, SR ;
BOOTH, RE .
SPINE, 1989, 14 (12) :1324-1331
[9]
OCHOA JA, 1991, J RHEUMATOL, V18, P580
[10]
PELKER RR, 1987, ORTHOP CLIN N AM, V18, P235