Artefacts in magnetic resonance imaging caused by dental material

被引:91
作者
Eggers, G
Rieker, M
Kress, B
Fiebach, J
Dickhaus, H
Hassfeld, S
机构
[1] Heidelberg Univ Hosp, Dept Oral & Craniomaxillofacial Surg, D-69120 Heidelberg, Germany
[2] Heidelberg Univ Hosp, Dept Neuroradiol, D-69120 Heidelberg, Germany
[3] Univ Heidelberg, Inst Med Biometry & Informat, D-6900 Heidelberg, Germany
关键词
MR tomography; artefacts; dental material;
D O I
10.1007/s10334-005-0101-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A common problem in computer tomography (CT) based imaging of the oral cavity is artefacts caused by dental restorations. The aim of this study was to investigate whether magnetic resonance imaging (MRI) of the oral cavity would be less affected than CT by artefacts caused by typical dental restorative alloys. In order to assess the extent of artefact generation, corresponding MRI scans of the same anatomic region with and without dental metal restorations were matched using a stereotactic frame. MRI imaging of the oral and maxillofacial region could be performed without reduction of the image quality by metallic dental restorations made from titanium, gold or amalgam. Dental restorations made from titanium, gold or amalgam did not reduce the image quality of the MRI sequence used in imaging of the oral and maxillofacial region for dental implant planning. In this respect MRI is superior to CT in implant planning.
引用
收藏
页码:103 / 111
页数:9
相关论文
共 14 条
[1]   Effect of interference of metallic objects on interpretation of T1-weighted magnetic resonance images in the maxillofacial region [J].
Abbaszadeh, K ;
Heffez, LB ;
Mafee, MF .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2000, 89 (06) :759-765
[2]   An assessment of the accuracy of ridge mapping in planning implant therapy for the anterior maxilla [J].
Allen, F ;
Smith, DG .
CLINICAL ORAL IMPLANTS RESEARCH, 2000, 11 (01) :34-38
[3]  
Bozorth R. M., 1993, FERROMAGNETISM
[4]  
FIALA TGS, 1993, PLAST RECONSTR SURG, V92, P1227
[5]  
Graf H, 2003, ROFO-FORTSCHR RONTG, V175, P1711
[6]   Advanced imaging: Magnetic resonance imaging in implant dentistry - A review [J].
Gray, CF ;
Redpath, TW ;
Smith, FW ;
Staff, RT .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (01) :18-27
[7]   Magnetic resonance tomography for planning dental implantation [Magnetresonanztomographie zur Planung vor dentaler Implantation.] [J].
Hassfeld S. ;
Fiebach J. ;
Widmann S. ;
Heiland S. ;
Mühling J. .
Mund-, Kiefer- und Gesichtschirurgie, 2001, 5 (3) :186-192
[8]   Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner [J].
Kamel, EM ;
Burger, C ;
Buck, A ;
von Schulthess, GK ;
Goerres, GW .
EUROPEAN RADIOLOGY, 2003, 13 (04) :724-728
[9]  
Kaneda T, 1998, AM J NEURORADIOL, V19, P317
[10]  
MAROLDI R, 2003, EUROPEAN RADIOLOGY, V13, pC20