Microfabricated capillary electrophoresis sensor for uranium (VI)

被引:66
作者
Collins, GE
Lu, Q
机构
[1] USN, Res Lab, Div Chem, Washington, DC 20375 USA
[2] Geocenters Inc, Rockville, MD 20852 USA
关键词
uranium (VI); microchip; capillary electrophoresis; arsenate III;
D O I
10.1016/S0003-2670(01)00903-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Arsenate III, a metallochromic ligand colorimetrically sensitive to the metal complexation of lanthanide and actinide metal ions, is applied to a capillary electrophoresis microchip for the detection of uranium (VI) and various lanthanide metal ions. The glass microchip contained 100 mum deep by 200 mum wide microchannels etched in a simple cross pattern with an 80 mm separation channel length and an 8 mm injection channel length. Detection of the Arsenate III metal complexes is achieved using a red light emitting diode (LED) light source and a photodiode array detector. Carbowax 20M is incorporated into the background electrolyte in order to eliminate the electroosmotic flow and prevent dye adsorption on the microchannel walls. Separation of uranium from four lanthanide metal ions is demonstrated in under 2 min. The addition of diethylenetriaminepentaacetic acid (DTPA) to the background electrolyte is found to be an effective means of eliminating any interference from lanthanide, transition and alkaline earth metal ions. Direct load injection of a pre-complexed metal ion mixture onto the microchannel gave a detection limit of 23 ppb uranium (VI) in the presence of seven lanthanide impurities (1.5 ppm each) in under 55 s. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:181 / 189
页数:9
相关论文
共 32 条
[1]  
CHENG KL, 1992, CRC HDB ORGANIC ANAL, P195
[2]  
COLLINS GE, IN PRESS ACTUATORS B
[3]   Microchip device for performing enzyme assays [J].
Hadd, AG ;
Raymond, DE ;
Halliwell, JW ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3407-3412
[4]   Development and operating characteristics of micro flow injection analysis systems based on electroosmotic flow - A review [J].
Haswell, SJ .
ANALYST, 1997, 122 (01) :R1-R10
[5]   Microfabricated capillary electrophoresis amino acid chirality analyzer for extraterrestrial exploration [J].
Hutt, LD ;
Glavin, DP ;
Bada, JL ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 1999, 71 (18) :4000-4006
[6]   HIGH-PERFORMANCE SEPARATION AND DETERMINATION OF CO(III) AND NI(II) CHELATES OF 4-(2-PYRIDYLAZO)RESORCINOL AT FEMTOMOLE LEVELS BY CAPILLARY ELECTROPHORESIS [J].
IKI, N ;
HOSHINO, H ;
YOTSUYANAGI, T .
CHEMISTRY LETTERS, 1993, (04) :701-704
[7]   FUSED QUARTZ SUBSTRATES FOR MICROCHIP ELECTROPHORESIS [J].
JACOBSON, SC ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2059-2063
[8]   SELECTIVE SPECTROPHOTOMETRIC METHOD FOR THE DETERMINATION OF URANIUM(VI) [J].
KADAM, BV ;
MAITI, B ;
SATHE, RM .
ANALYST, 1981, 106 (1263) :724-726
[9]  
Kutter JP, 1998, J MICROCOLUMN SEP, V10, P313, DOI 10.1002/(SICI)1520-667X(1998)10:4<313::AID-MCS1>3.0.CO
[10]  
2-J