A microvolumetric β blood counter for pharmacokinetic PET studies in small animals

被引:10
作者
Convert, L. [1 ]
Morin-Brassard, G.
Cadorette, J.
Rouleau, D.
Croteau, E.
Archambault, M.
Fontaine, R.
Lecomte, R.
机构
[1] Univ Sherbrooke, Sherbooke Mol Imaging Ctr, Dept Nucl Med & Radiobiol, Sherbrooke, PQ J1H 5N4, Canada
[2] Univ Sherbrooke, Dept Elect & Comp Engn, Sherbrooke, PQ J1K 2R1, Canada
基金
加拿大健康研究院;
关键词
beta (beta) detector; blood sampling; pharmacokinetic modeling; small animal PET;
D O I
10.1109/TNS.2006.889166
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radiotracer kinetic modeling in small animals with Positron Emission Tomography (PET) requires the determination of the blood tracer concentration as a function of time. A continuous blood counting system was designed to measure the input function from rats and mice in real time. The system consists of a flow-through 0 counter made of silicon PIN photodiodes and a mu l syringe pump. The latter draws blood continuously from an implanted venous or arterial catheter, at a user selected rate. The direct beta detection by photodiodes minimizes the shield footprint next to the animal and reduces the counter sensitivity to ambient gamma radiation. The device is entirely remote controlled for sampling protocol selection, tuning, and real time monitoring of measured parameters. It can be hooked to a computer or fully integrated with the LabPET (TM) scanner for blood counting during dynamic PET imaging experiments. The counter sensitivity to the most popular PET radioisotopes (F-18, Cu-64, N-13, 11C) ranges from 7.1 to 46.8 Bq/mu l. Its linearity is better than 98% up to 46 kBq/mu l for F-18, and a 1.4 s dispersion constant was measured at a rate of 250 mu l/min with rat whole blood in a PE10' catheter. Due to its optimized mechanical design and compact shielding, the counter sensitivity to radioactive background is only 5 counts per second (cps) for a 37 MBq F-18 source 10 cm away from the detector. Accurate time-activity curves have been obtained from rats and mice in dynamic PET imaging studies.
引用
收藏
页码:173 / 180
页数:8
相关论文
共 20 条
[1]   USE OF THE ISOLATED PERFUSED HEART FOR EVALUATION OF CARDIAC TOXICITY [J].
ANDERSON, PG ;
DIGERNESS, SB ;
SKLAR, JL ;
BOOR, PJ .
TOXICOLOGIC PATHOLOGY, 1990, 18 (04) :497-510
[2]   Molecular imaging of small animals with dedicated PET tomographs [J].
Chatziioannou, AF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2002, 29 (01) :98-114
[3]  
Cherry S R, 2001, ILAR J, V42, P219
[4]   Animal models for imaging [J].
Croft, BY .
DISEASE MARKERS, 2002, 18 (5-6) :365-374
[5]  
CROTEAU E, 2004, MOL IMAGING BIOL, V6, P94
[6]   Isolated working heart: Description of models relevant to radioisotopic and pharmacological assessments [J].
Depre, C .
NUCLEAR MEDICINE AND BIOLOGY, 1998, 25 (08) :711-713
[7]   A good practice guide to the administration of substances and removal of blood, including routes and volumes [J].
Diehl, KH ;
Hull, R ;
Morton, D ;
Pfister, R ;
Rabemampianina, Y ;
Smith, D ;
Vidal, JM ;
van de Vorstenbosch, C .
JOURNAL OF APPLIED TOXICOLOGY, 2001, 21 (01) :15-23
[8]   AUTOMATED BLOOD-SAMPLING SYSTEMS FOR POSITRON EMISSION TOMOGRAPHY [J].
ERIKSSON, L ;
HOLTE, S ;
BOHM, C ;
KESSELBERG, M ;
HOVANDER, B .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :703-707
[9]  
ERIKSSON L, 1991, MED PROG TECHNOL, V17, P249
[10]  
GRAHAM MM, 1993, J NUCL MED, V34, P1357