Bioreactors for heart valve tissue engineering: a review

被引:8
作者
Amrollahi, Pouya [2 ]
Tayebi, Lobat [1 ,3 ]
机构
[1] Marquette Univ, Sch Dent, Dept Dev Sci, Milwaukee, WI 53233 USA
[2] Oklahoma State Univ, Sch Mat Sci & Engn, Helmerich Adv Technol Res Ctr, Tulsa, OK 74106 USA
[3] Univ Oxford, Dept Engn Sci, Parks Rd, Oxford OX1 3PJ, England
关键词
heart valves; bioreactors; tissue engineering; tissue-engineered heart valves; IN-VITRO DEVELOPMENT; AORTIC-VALVE; CYCLIC STRETCH; ELECTROPHORETIC DEPOSITION; ELASTOMERIC SCAFFOLDS; PULSATILE BIOREACTOR; DEGRADATION BEHAVIOR; COLLAGEN; BIOMATERIALS; DESIGN;
D O I
10.1002/jctb.4825
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 [微生物学]; 090105 [作物生产系统与生态工程];
摘要
Bioreactors have great potential in the successful development of tissue-engineered heart valve replacements, both at the research stage and in commercial platforms. Their ability to mimick the chemical and physiological conditions of the body has allowed researchers to study in vitro cellular responses, and this has helped in the fabrication of better and more efficient tissues in vivo. Use of different bioreactors, such as, rotating, dynamic flexure, cyclic stretch and pulsatile bioreactors, in tissue engineering of heart valves has been widely investigated. However, this research is still at its early stage, and many critical issues need to be resolved to make tissue engineered heart valves sufficiently reliable for clinical applications. In the following article, after a brief introduction to the structure and role of heart valves, the efforts of tissue engineers in designing heart valves using different bioreactors is described. (c) 2015 Society of Chemical Industry
引用
收藏
页码:847 / 856
页数:10
相关论文
共 124 条
[1]
Microstructural manipulation of electrospun scaffolds for specific bending stiffness for heart valve tissue engineering [J].
Amoroso, Nicholas J. ;
D'Amore, Antonio ;
Hong, Yi ;
Rivera, Christian P. ;
Sacks, Michael S. ;
Wagner, William R. .
ACTA BIOMATERIALIA, 2012, 8 (12) :4268-4277
[2]
[Anonymous], 2014, PHYS SCI INT J
[3]
Multi-scale mechanical characterization of scaffolds for heart valve tissue engineering [J].
Argento, G. ;
Simonet, M. ;
Oomens, C. W. J. ;
Baaijens, F. P. T. .
JOURNAL OF BIOMECHANICS, 2012, 45 (16) :2893-2898
[4]
Aupart MR, 2006, J HEART VALVE DIS, V15, P768
[5]
An ex vivo study of the biological properties of porcine aortic valves in response to circumferential cyclic stretch [J].
Balachandran, Kartik ;
Konduri, Suchitra ;
Sucosky, Philippe ;
Jo, Hanjoong ;
Yoganathan, Ajit P. .
ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (11) :1655-1665
[6]
Elevated cyclic stretch alters matrix remodeling in aortic valve cusps: implications for degenerative aortic valve disease [J].
Balachandran, Kartik ;
Sucosky, Philippe ;
Jo, Hanjoong ;
Yoganathan, Ajit P. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2009, 296 (03) :H756-H764
[7]
Design and Validation of a Novel Splashing Bioreactor System for Use in Mitral Valve Organ Culture [J].
Barzilla, Janet E. ;
McKenney, Anna S. ;
Cowan, Ashley E. ;
Durst, Christopher A. ;
Grande-Allen, K. Jane .
ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (11) :3280-3294
[8]
Control of an air pressure actuated disposable bioreactor for cultivating heart valves [J].
Beelen, M. J. ;
Neerincx, P. E. ;
van de Molengraft, M. J. G. .
MECHATRONICS, 2011, 21 (08) :1288-1297
[9]
Bioreactors for Development of Tissue Engineered Heart Valves [J].
Berry, Joel L. ;
Steen, Julie A. ;
Williams, J. Koudy ;
Jordan, James E. ;
Atala, Anthony ;
Yoo, James J. .
ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (11) :3272-3279
[10]
Bhumiratana S, 2014, PRINCIPLES OF TISSUE ENGINEERING, 4TH EDITION, P261, DOI 10.1016/B978-0-12-398358-9.00014-8