Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation

被引:127
作者
Achenbach, S [1 ]
Ropers, D [1 ]
Pohle, FK [1 ]
Raaz, D [1 ]
von Erffa, J [1 ]
Yilmaz, A [1 ]
Muschiol, G [1 ]
Daniel, WG [1 ]
机构
[1] Univ Erlangen Nurnberg, Dept Internal Med Cardiol 2, D-91054 Erlangen, Germany
关键词
computed tomography; coronary artery stenoses; coronary artery disease;
D O I
10.1093/eurheartj/ehi326
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Aims Insufficient spatial and temporal resolutions have limited image quality and accuracy of multi-detector CT (MDCT) for coronary artery visualization and detection of stenoses. We assessed the accuracy of a new 16-slice scanner with 370 ms rotation and 0.75 mm collimation for detection of coronary stenoses using an analysis approach based on coronary artery segments. Methods and results Fifty consecutive patients scheduled for diagnostic coronary angiography in stable clinical condition and sinus rhythm were enrolled. All patients with a heart rate > 60 b.p.m. received 100 mg atenolol p.o. and up to four doses of 5 mg metoprolol i.v. before the scan. MDCT was performed using 16x0.75 mm collimation, 120 kV, and ECG-gated tube current modulation. Ninety millilitres of contrast agent was injected intravenously. MDCT images were visually analysed using the 16-segment coronary artery model of the American Heart Association and compared with invasive, quantitative coronary angiography in a blinded fashion. A significant stenosis was assumed if the diameter reduction was >= 50%. Mean heart rate was 58 b.p.m. during MDCT. After exclusion of two patients with not fully evaluable data sets, MDCT correctly identified at least one coronary stenosis in all 25 patients with significant coronary lesions in angiography and correctly demonstrated the absence of stenoses in 19/23 patients (sensitivity 100%, specificity 83%). Sensitivity and specificity for all 50 patients were 93 and 83%, respectively. On a per-segment basis, nine coronary segments distal of total occlusions and 128 coronary segments with a reference diameter < 1.5 mm were excluded from the analysis. Twenty-eight of the included 663 segments (4%) were unevaluable due to calcification or motion artefact. In the remaining 635 segments, 50/53 stenoses were detected by MDCT (sensitivity 94%, specificity 96%, negative predictive value 99%, positive predictive value 69%). Conclusion Increasing temporal and spatial resolutions of MDCT lead to improved evaluation and diagnostic accuracy for detection of coronary stenoses.
引用
收藏
页码:1978 / 1986
页数:9
相关论文
共 28 条
[1]
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]
Noninvasive coronary angiography - An acceptable alternative? [J].
Achenbach, S ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (26) :1909-1910
[3]
Achenbach S, 2001, CIRCULATION, V103, P2535
[4]
Becker CR, 2000, RADIOLOGE, V40, P118, DOI 10.1007/s001170050019
[5]
Detection of coronary artery stenoses with multislice helical CT angiography [J].
Becker, CR ;
Knez, A ;
Leber, A ;
Treede, H ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (05) :750-755
[6]
ACC/AHA/ACP-ASIM guidelines for the management of patients with chronic stable angina: Executive summary and recommendations - A report of the American College of Cardiology American Heart Association Task Force on Practice Guidelines (Committee on Management of Patients with Chronic Stable Angina) [J].
Gibbons, RJ ;
Chatterjee, K ;
Daley, J ;
Douglas, JS ;
Fihn, SD ;
Gardin, JM ;
Grunwald, MA ;
Levy, D ;
Lytle, BW ;
O'Rourke, RA ;
Schafer, WP ;
Williams, SV ;
Ritchie, JL ;
Gibbons, RJ ;
Cheitlin, MD ;
Eagle, KA ;
Gardner, TJ ;
Garson, A ;
Russell, RO ;
Ryan, TJ ;
Smith, SC .
CIRCULATION, 1999, 99 (21) :2829-2848
[7]
Evaluation of left ventricular dysfunction using multiphasic reconstructions of coronary multi-slice computed tomography data in patients with chronic ischemic heart disease: validation against cine magnetic resonance imaging [J].
Halliburton, SS ;
Petersilka, M ;
Schvartzman, PR ;
Obuchowski, N ;
White, RD .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2003, 19 (01) :73-83
[8]
Heart-rate-adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality [J].
Herzog, C ;
Abolmaali, N ;
Balzer, JO ;
Baunach, S ;
Ackermann, H ;
Dogan, S ;
Britten, MB ;
Vogl, TJ .
EUROPEAN RADIOLOGY, 2002, 12 (11) :2670-2678
[9]
Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643
[10]
Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT [J].
Hunold, P ;
Vogt, FM ;
Schmermund, A ;
Debatin, JF ;
Kerkhoff, G ;
Budde, T ;
Erbel, R ;
Ewen, K ;
Barkhausen, J .
RADIOLOGY, 2003, 226 (01) :145-152