Novel PVC membrane-based thoron ion selective electrode and its application: Determination of zirconium

被引:15
作者
Arida, Hassan A. [1 ]
机构
[1] Atom Energy Author, Hot Labs Ctr, Cairo 13759, Egypt
关键词
thoron; ion selective electrode; zirconium determination; indirect potentiometry;
D O I
10.1016/j.talanta.2008.01.061
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction, electrochemical evaluation and application of new electrode selective to the thoron reagent are reported. The electrode incorporates bathophenanthroline iron: thoron ion pair as electroactive sensing material, o-nitrophenyl octyl ether as plasticizer and PVC as support matrix, exhibits a Nemstian response to thoron with a slope of -29.7 +/- 1 mV per decade in a range of concentration from 1.0 x 10(-6) to 5.0 x 10(-2) mol L-1, a detection limit of 6.0 x 10(-7) mol L-1 and fast response time of less than 30 s. The proposed electrode is successfully applied to zirconium ion determination in aqueous samples using indirect potentiometry and the results obtained are compared with those provided by spectrophotometric analysis using thoron as complexing agent. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:40 / 43
页数:4
相关论文
共 28 条
[1]   Anion selective potentiometric sensor based on gallium nitride crystalline membrane [J].
Alifragis, Y ;
Konstantinidis, G ;
Georgakilas, A ;
Chaniotakis, N .
ELECTROANALYSIS, 2005, 17 (5-6) :527-531
[2]   A novel 8-hydroxyquinoline PVC coated graphite sensor for potentiometric determination of some metal ions [J].
Arida, HAM .
ANALYTICAL LETTERS, 2002, 35 (15) :2421-2431
[3]   APPLICATION OF CATALYTIC STRIPPING VOLTAMMETRY FOR THE DETERMINATION OF ORGANIC SULFUR-COMPOUNDS AT A HANGING MERCURY DROP ELECTRODE - BEHAVIOR OF CYSTEINE, CYSTINE AND N-ACETYLCYSTEINE IN THE PRESENCE OF NICKEL ION [J].
BANICA, FG ;
MOREIRA, JC ;
FOGG, AG .
ANALYST, 1994, 119 (02) :309-318
[4]   Modern electrochemical methods for monitoring of chemical carcinogens [J].
Barek, J ;
Moreira, JC ;
Zima, J .
SENSORS, 2005, 5 (4-5) :148-158
[5]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[6]   Voltammetry as a virtual potentiometric sensor in modeling of a metal-ligand system and refinement of stability constants. Part 1. Polarographic and glass electrode potentiometric study of a dynamic Cd-glycine system [J].
Cukrowski, I ;
Zhang, JM .
ELECTROANALYSIS, 2004, 16 (08) :612-626
[7]   A highly selective potentiometric sensor of molybdate based on a μ-oxo-bridged manganeseporphyrin dimer [J].
Fang, Zheng-Hui ;
Han, Zhi-Xiang ;
Zhang, Xiao-Bing ;
Shen, Guo-Li ;
Yu, Ru-Qin .
ANALYTICAL SCIENCES, 2006, 22 (07) :949-953
[8]   Multicommuted fluorometric multiparameter sensor for simultaneous determination of naproxen and salicylic acid in biological fluids [J].
Garcia-Reyes, Juan F. ;
Ortega-Barrales, Pilar ;
Molina-Diaz, Antonio .
ANALYTICAL SCIENCES, 2007, 23 (04) :423-428
[9]  
GUPTA GP, 1975, ANAL CHEM, V277, P206
[10]   Anion recognition through modified calixarenes: a highly selective sensor for monohydrogen phosphate [J].
Gupta, VK ;
Ludwig, R ;
Agarwal, S .
ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) :213-218