Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method

被引:80
作者
Itoh, K [1 ]
机构
[1] JR Sapporo Gen Hosp, Dept Radiol, Chuo Ku, Sapporo, Hokkaido 0600033, Japan
关键词
glomerular filtration rate; renography; Cockcroft-Gault's equation; plasma sample method; Tc-99m-DTPA;
D O I
10.1007/BF03006669
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The gamma camera uptake method with Tc-99m-DTPA is simple and less time consuming for the determination of the glomerular filtration rate (GFR). However, its diagnostic accuracy is debated. Gates' method and predicted creatinine clearance method were compared with plasma clearance method with Tc-99m-DTPA for the measurement of GFR. Materials and Methods: Tc-99m-DTPA renography was performed on 133 patients (69 males and 64 females; age range being 24 to 84 years) with a wide range of renal function. The GFR was determined simultaneously by 3 methods; (1) gamma camera uptake method (modified Gates, Gates); (2) predicted creatinine clearance method (Cockcroft-Gault, CG); (3) single- or two-plasma clearance method (plasma sample clearance method, PSC). The PSC was chosen as a reference. Results: The regression equation of the Gates and the CG against the PSC was Y = 11.89 + 1.041X (r = 0.790, p < 0.001, RMSE = 23.55 ml/min/1.73 m(2)) and Y= 8.845 + 0.7899X (r = 0.8270, p < 0.001, RMSE = 16.27 ml/min/1.73 m(2)), respectively. In comparison with the GFR by PSC, the Gates tended to overestimate the GFR, and contrarily the CG tended to underestimate the GFR. Conclusion: The Gates correlates well with the PSC. However, the Gates is even less precise than the CG. The Gates' method in Tc-99m-DTPA renography is not suitable for the estimation of GFR in routine practice.
引用
收藏
页码:561 / 565
页数:5
相关论文
共 33 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Blaufox MD, 1996, J NUCL MED, V37, P1883
[4]  
BROCHNERMORTENS.J, 1983, CLIN PHYSL, V8, P1
[5]  
BROCHNERMORTENSEN J, 1978, DAN MED BULL, V25, P181
[6]  
CHRISTENSEN AB, 1992, CLIN PHYSL, V19, P827
[7]   PREDICTION OF CREATININE CLEARANCE FROM SERUM CREATININE [J].
COCKCROFT, DW ;
GAULT, MH .
NEPHRON, 1976, 16 (01) :31-41
[8]   Measurement of glomerular filtration rate by the 99mTc-DTPA renogram is less precise than measured and predicted creatinine clearance [J].
De Santo, NG ;
Anastasio, P ;
Cirillo, M ;
Santoro, D ;
Spitali, L ;
Mansi, L ;
Celentano, L ;
Capodicasa, D ;
Cirillo, E ;
Del Vecchio, E ;
Pascale, C ;
Capasso, G .
NEPHRON, 1999, 81 (02) :136-140
[9]  
Duran E, 1997, RADIONUCLIDES NEPHRO, P112
[10]   COMPARATIVE-ASSESSMENT OF TECHNIQUES FOR ESTIMATION OF GLOMERULAR-FILTRATION RATE WITH TC-99M-DTPA [J].
FAWDRY, RM ;
GRUENEWALD, SM ;
COLLINS, LT ;
ROBERTS, AJ .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1985, 11 (01) :7-12