Reliability of a new hand-held dynamometer in measuring shoulder range of motion and strength

被引:64
作者
Cadogan, Angela [1 ,2 ]
Laslett, Mark [1 ,2 ,3 ]
Hing, Wayne [1 ,2 ]
McNair, Peter [1 ,2 ]
Williams, Maynard [1 ,2 ]
机构
[1] AUT Univ, Hlth & Rehabil Res Inst, Auckland 1142, New Zealand
[2] AUT Univ, Sch Rehabil & Occupat Studies, Fac Hlth & Environm Sci, Auckland 1142, New Zealand
[3] Physiosouth, Christchurch, New Zealand
关键词
Shoulder pain; Physical examination; Reliability; Hand-held dynamometer; CLINICAL MEASUREMENT; REPRODUCIBILITY; AGREEMENT; MOVEMENT; IMPACT;
D O I
10.1016/j.math.2010.05.005
中图分类号
R49 [康复医学];
学科分类号
100232 [康复医学];
摘要
Acceptable reliability is a prerequisite for inclusion of physical examination tests in clinical examinations of the painful shoulder. The aim of this study was to establish the intraexaminer and interexaminer reliability of measures of shoulder range of motion (ROM) and muscle force using a new hand-held dynamometer with the ability to standardize overpressure force during passive ROM tests. Forty consecutive subjects with shoulder pain were recruited, and tests were performed by two physiotherapists. Tests included active ROM elevation, passive ROM glenohumeral abduction and external rotation and resisted abduction and external rotation. All tests demonstrated high levels of intraexaminer reliability (ICC 0.85-0.99; LOA 6-24 degrees and 1.1-7.0 kg). Highest levels of interexaminer reliability reliability were observed for measures of active ROM flexion (ICC 0.88-0.95; LOA 14-22 degrees). Passive ROM tests demonstrated 'moderate - substantial' interexaminer reliability (ICC 0.45-0.62; LOA 25-34 degrees). The ICCs for resisted tests ranged from 0.68 to 0.84, and LOA ranged from 3.2 to 8.5 kg. Active ROM flexion demonstrated high levels of both intra- and interexaminer reliability. Measures of passive ROM and peak isometric force demonstrated acceptable levels of intraexaminer reliability. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:97 / 101
页数:5
相关论文
共 26 条
[1]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]
RELIABILITY OF GONIOMETRIC MEASUREMENTS [J].
BOONE, DC ;
AZEN, SP ;
LIN, CM ;
SPENCE, C ;
BARON, C ;
LEE, L .
PHYSICAL THERAPY, 1978, 58 (11) :1355-1360
[3]
CLARYS JP, 1986, HUM BIOL, V58, P771
[4]
CONSTANT CR, 1987, CLIN ORTHOP RELAT R, P160
[5]
Cyriax J, 1982, DIAGNOSIS SOFT TISSU, V1, P49
[6]
Diagnostic criteria for upper limp disorders in epidemiological studies [J].
Davis, TRC .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1998, 23B (05) :567-569
[7]
ELLENBECKER TS, 1996, ISOKINET EXERC SCI, V6, P51
[8]
CLINICAL MEASUREMENT OF RANGE OF MOTION - REVIEW OF GONIOMETRY EMPHASIZING RELIABILITY AND VALIDITY [J].
GAJDOSIK, RL ;
BOHANNON, RW .
PHYSICAL THERAPY, 1987, 67 (12) :1867-1872
[9]
Surveillance case definitions for work related upper limb pain syndromes [J].
Harrington, JM ;
Carter, JT ;
Birrell, L ;
Gompertz, D .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1998, 55 (04) :264-271
[10]
Reliability of five methods for assessing shoulder range of motion [J].
Hayes, K ;
Walton, JR ;
Szomor, ZL ;
Murrell, GAC .
AUSTRALIAN JOURNAL OF PHYSIOTHERAPY, 2001, 47 (04) :289-294