Quantifying paraspinal muscle tone and stiffness in young adults with chronic low back pain: a reliability study

被引:66
作者
Hu, Xiaoqian [1 ]
Lei, Di [1 ]
Li, Le [1 ]
Leng, Yan [1 ]
Yu, Qiuhua [1 ]
Wei, Xiaoyu [1 ]
Lo, Wai Leung Ambrose [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Guangdong Engn & Technol Res Ctr Rehabil Med & Tr, Dept Rehabil Med, Guangzhou 510080, Guangdong, Peoples R China
[2] UCL, Dept Elect & Elect Engn, Torrington Pl, London WC1E 7JE, England
基金
中国博士后科学基金;
关键词
SURFACE ELECTROMYOGRAPHY; MECHANICAL-PROPERTIES; TISSUE STIFFNESS; NECK PAIN; VALIDITY; MOTION; ELASTOGRAPHY; ELASTICITY; PALPATION; AGREEMENT;
D O I
10.1038/s41598-018-32418-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
070301 [无机化学]; 070403 [天体物理学]; 070507 [自然资源与国土空间规划学]; 090105 [作物生产系统与生态工程];
摘要
The reliability of a handheld myotonometer when used in a clinical setting to assess paraspinal muscle mechanical properties is unclear. This study aimed to investigate the between-session intra-rater reliability of a handheld myotonometer in young adults with low back pain (LBP) in a clinical environment. One assessor recorded lumbar paraspinal muscle tone and stiffness in an outpatient department on two occasions. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD) and Bland-Altman analysis were conducted to assess reliability. The results indicated acceptable between-days intra-rater reliability (ICC > 0.75) for all measurements. The SEM of the muscle tone and stiffness measurements ranged between 0.20-0.66 Hz and 7.91-16.51 N/m, respectively. The SRD was 0.44-1.83 Hz for muscle tone and 21.93-52.87 N/m for muscle stiffness. SEM and SRD at L-1-L-2 were higher than those at other levels. The magnitude of agreement appeared to decrease as muscle tone and stiffness increased. The myotonometer demonstrated acceptable reliability when used in a clinical setting in young adults with chronic LBP. Measurements of the upper lumbar levels were not as reliable as those of the lower lumbar levels. The crural attachment of the diaphragm at L-1 and L-2 may affect paraspinal muscle tone and stiffness during respiratory cycles.
引用
收藏
页数:10
相关论文
共 51 条
[1]
Manual physical assessment of spinal segmental motion: Intent and validity [J].
Abbott, J. Haxby ;
Flynn, Timothy W. ;
Fritz, Julie M. ;
Hing, Wayne A. ;
Reid, Duncan ;
Whitman, Julie M. .
MANUAL THERAPY, 2009, 14 (01) :36-44
[2]
Measurement of ageing effects on muscle tone and mechanical properties of rectus femoris and biceps brachii in healthy males and females using a novel hand-held myometric device [J].
Agyapong-Badu, Sandra ;
Warner, Martin ;
Samuel, Dinesh ;
Stokes, Maria .
ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2016, 62 :59-67
[3]
Quadriceps muscle tone, elasticity and stiffness in older males: Reliability and symmetry using the MyotonPRO [J].
Aird, Lucy ;
Samuel, Dinesh ;
Stokes, Maria .
ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2012, 55 (02) :E31-E39
[4]
Greater Resting Lumbar Extensor Myofascial Stiffness in Younger Ankylosing Spondylitis Patients Than Age-Comparable Healthy Volunteers Quantified by Myotonometry [J].
Andonian, Brian J. ;
Masi, Alfonse T. ;
Aldag, Jean C. ;
Barry, Alexander J. ;
Coates, Brandon A. ;
Emrich, Katherine ;
Henderson, Jacqueline ;
Kelly, Joseph ;
Nair, Kalyani .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2015, 96 (11) :2041-2047
[5]
Feasibility of the use of a novel soft tissue stiffness meter [J].
Arokoski, JPA ;
Surakka, J ;
Ojala, T ;
Kolari, P ;
Jurvelin, JS .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (03) :215-228
[6]
Bailey L., 2013, J NEUROLOGICAL DISOR, V1, P1000116, DOI 10.4172/2329-6895.1000116
[7]
Reliability of a new, hand-held device for assessing skeletal muscle stiffness [J].
Bizzini, M ;
Mannion, AF .
CLINICAL BIOMECHANICS, 2003, 18 (05) :459-461
[8]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]
Bruton A., 2000, PHYSIOTHERAPY, V86, P94, DOI [DOI 10.1016/S0031-9406(05)61211-4, 10.1016/S0031-9406(05)61211-4]
[10]
Quantitative Mechanical Properties of the Relaxed Biceps and Triceps Brachii Muscles in Patients with Subacute Stroke: A Reliability Study of the Myoton-3 Myometer [J].
Chuang, Li-ling ;
Wu, Ching-yi ;
Lin, Keh-chung ;
Lur, Shih-yu .
STROKE RESEARCH AND TREATMENT, 2012, 2012