High resolution inductively coupled plasma mass spectrometry allows rapid assessment of iron absorption in infants and children
被引:30
作者:
Chen, ZS
论文数: 0引用数: 0
h-index: 0
机构:
Baylor Coll Med, Dept Pediat, UD Dept Agr, ARS Childrens Nutr Res Ctr, Houston, TX 77030 USABaylor Coll Med, Dept Pediat, UD Dept Agr, ARS Childrens Nutr Res Ctr, Houston, TX 77030 USA
Chen, ZS
[1
]
Griffin, IJ
论文数: 0引用数: 0
h-index: 0
机构:
Baylor Coll Med, Dept Pediat, UD Dept Agr, ARS Childrens Nutr Res Ctr, Houston, TX 77030 USABaylor Coll Med, Dept Pediat, UD Dept Agr, ARS Childrens Nutr Res Ctr, Houston, TX 77030 USA
Griffin, IJ
[1
]
Plumlee, LM
论文数: 0引用数: 0
h-index: 0
机构:
Baylor Coll Med, Dept Pediat, UD Dept Agr, ARS Childrens Nutr Res Ctr, Houston, TX 77030 USABaylor Coll Med, Dept Pediat, UD Dept Agr, ARS Childrens Nutr Res Ctr, Houston, TX 77030 USA
Plumlee, LM
[1
]
Abrams, SA
论文数: 0引用数: 0
h-index: 0
机构:
Baylor Coll Med, Dept Pediat, UD Dept Agr, ARS Childrens Nutr Res Ctr, Houston, TX 77030 USABaylor Coll Med, Dept Pediat, UD Dept Agr, ARS Childrens Nutr Res Ctr, Houston, TX 77030 USA
Abrams, SA
[1
]
机构:
[1] Baylor Coll Med, Dept Pediat, UD Dept Agr, ARS Childrens Nutr Res Ctr, Houston, TX 77030 USA
inductively coupled plasma MS;
iron absorption;
isobaric interference;
mass bias;
stable isotopes;
D O I:
10.1093/jn/135.7.1790
中图分类号:
R15 [营养卫生、食品卫生];
TS201 [基础科学];
学科分类号:
100403 [营养与食品卫生学];
摘要:
Stable isotope absorption studies of iron have been limited by the high cost and limited availability of isotope ratio analysis using thermal ionization MS (TIMS). The development of high-resolution double focusing inductively coupled plasma MS (ICIP-MS) may permit more cost-efficient sample analysis due to its high throughput, lower cost, easy sample pretreatment, and greater availability. Our objective was to develop an ICP-MS methodology for the measurement of iron isotope ratios using very small blood volumes. We developed a technique using multiple iron-nickel mixing standard solutions to adjust for nickel interference calibration. RBC samples from human subjects previously given Fe-58 and Fe-57 were analyzed for iron isotope ratios and compared with our current methodology (TIMS). Reproducibility of iron isotope ratios provided external relative SD < 0.5 and 0.7% (1 SD) for Fe-57/Fe-54 and Fe-58/Fe-54, respectively. Iron isotope ratios from ICP-MS analysis did not differ from those from TIMS based on statistical analyses, nor did the calculated iron absorption values. The mean and SD of iron absorption did not differ when measured by TIMS or ICIP-MS. A 2-mu L RBC sample was sufficient for ICP-MS iron isotope ratio analysis with an internal relative SD < 0.5% and analytical time < 5 min. This technique may assist groups in increasing their use of stable isotope methods to assess iron absorption in infants and children.