Cascade control of a distributed collector solar field

被引:41
作者
Silva, RN [1 ]
Rato, LM [1 ]
Lemos, JM [1 ]
Coito, F [1 ]
机构
[1] INESC,P-1000 LISBON,PORTUGAL
关键词
process control; predictive control; adaptive control; solar energy; cascade control;
D O I
10.1016/S0959-1524(96)00019-4
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper reports experimental results on the cascade control of a distributed collector solar field. The control problem consists of keeping constant the field outlet oil temperature by acting on the circulating oil flow used for heat transfer. In the inner loop an adaptive model based predictive controller exploiting the information conveyed by accessible disturbances (radiation changes and inlet oil temperature) is used, while in the outer loop a PID is employed. The need for adaptive control arises from the time varying behaviour of the plant. Due to the generality of the methods employed, the experience reported is relevant to a wide class of industrial processes. (C) 1997 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 9 条
[1]  
Camacho E. F., 1994, IEEE Transactions on Control Systems Technology, V2, P462, DOI 10.1109/87.338667
[2]  
CAMACHO EF, 1992, IEEE CONTROL SYS APR
[3]   INDIRECT AND IMPLICIT ADAPTIVE PREDICTIVE CONTROL OF THE BENCHMARK PLANT [J].
CHISCI, L ;
GIARRE, L ;
MOSCA, E .
AUTOMATICA, 1994, 30 (04) :577-584
[4]  
COITO F, 1995, INESC J RES DEV, V5, P49
[5]  
Coito F. J., 1995, Proceedings of the Third European Control Conference. ECC 95, P476
[6]   PERFORMANCE IMPROVEMENTS OF SELF-TUNING CONTROLLERS BY MULTISTEP HORIZONS - THE MUSMAR APPROACH [J].
GRECO, C ;
MENGA, G ;
MOSCA, E ;
ZAPPA, G .
AUTOMATICA, 1984, 20 (05) :681-699
[7]   RESONANCE CHARACTERISTICS OF DISTRIBUTED SOLAR COLLECTOR FIELDS [J].
MEABURN, A ;
HUGHES, FM .
SOLAR ENERGY, 1993, 51 (03) :215-221
[8]   ROBUSTNESS OF MULTIPREDICTOR ADAPTIVE REGULATORS - MUSMAR [J].
MOSCA, E ;
ZAPPA, G ;
LEMOS, JM .
AUTOMATICA, 1989, 25 (04) :521-529
[9]  
[No title captured]