A comparison of the monitors INVOS3100 and NIRO500 in detecting changes in cerebral oxygenation

被引:41
作者
Grubhofer, G
Tonninger, W
Keznicki, P
Skyllouriotis, P
Ehrlich, M
Hiesmayr, M
Lassnigg, A
机构
[1] Univ Clin Vienna, Dept Cardiothorac & Vasc Anaesthesia & Intens Care, Vienna, Austria
[2] Univ Clin Vienna, Dept Cardiac & Thorac Surg, Vienna, Austria
关键词
brain metabolism; oxygenation; cerebral; near-infrared spectroscopy; hemoglobins; oxyhemoglobins; carbon dioxide physiology; comparative study;
D O I
10.1034/j.1399-6576.1999.430417.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Measurements of cerebral haemoglobin oxygenation of 2 near-infrared spectroscopy devices (INVOS 3100 and NIRO 500) were compared during and after hypocapnia. Methods: Fifteen awake, healthy volunteers, who hyperventilated to obtain end-tidal CO2 (EtCO2) values of approximately 20 mmHg, were studied. During hyperventilation and 8 min thereafter, EtCO2, INVOS 3100 (RSO2=regional cerebral oxygenation) and NIRO 500 recordings (HbO(2)=oxyhaemoglobin, Hb= deoxyhaemoglobin, Hb-diff=HbO(2)-Hb CtO(2)=oxidised cytochrome oxidase aa3) were analysed. Results: Hyperventilation induced a significant decline in EtCO2 from 30.5 to 14.7 mmHg (P<0.001) and RSO2 from 67.1% to 62.7% (P=0.025). At hypocapnia, only Hb (+1.61+/-0.48 mu mol/L; P<0.001) and Hb-diff (-3.01+/-2.0 mu mol/L; P<0.001) indicated a decline in cerebral haemoglobin oxygenation. Within 8 min after hyperventilation, both EtCO2 and RSO2 normalised to values insignificantly different from baseline. In contrast, Hb and Hb-diff remained significantly different (Hb: +2.52+/-1.28 mu mol/l; P<0.001, Hb-diff: -4.31+/-4.0 mu mol/L; P<0.001). A correlation with EtCO2 was found for RSO2 (R=0.35; P<0.001) and CtO(2) (R=0.42; P<0.001). AU volunteers were continuously awake and none presented clinical symptoms of cerebral hypoxia. Conclusion: Changes in cerebral haemoglobin oxygenation state were reflected more accurately by INVOS 3100 than NIRO 500. The cause may be the different technology of the monitors, since INVOS 3100 eliminates the contribution of extracranial oxygenation.
引用
收藏
页码:470 / 475
页数:6
相关论文
共 28 条
[1]  
Colier W N, 1995, Acta Anaesthesiol Scand Suppl, V107, P101
[2]   Measurement of cytochrome oxidase and mitochondrial energetics by near-infrared spectroscopy [J].
Cooper, CE ;
Springett, R .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 1997, 352 (1354) :669-676
[3]   CEREBRAL OXIMETRY - A USEFUL MONITOR DURING CAROTID-ARTERY SURGERY [J].
DUNCAN, LA ;
RUCKLEY, CV ;
WILDSMITH, JAW .
ANAESTHESIA, 1995, 50 (12) :1041-1045
[4]  
DUPLESSIS AJ, 1995, ANN NEUROL, V37, P488
[5]  
Dweidner A, 1975, Acta Neurochir (Wien), V32, P175
[6]   CAT BRAIN CYTOCHROME-C-OXIDASE REDOX CHANGES INDUCED BY HYPOXIA AFTER BLOOD-FLUOROCARBON EXCHANGE-TRANSFUSION [J].
FERRARI, M ;
WILLIAMS, MA ;
WILSON, DA ;
THAKOR, NV ;
TRAYSTMAN, RJ ;
HANLEY, DF .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 269 (02) :H417-H424
[7]   EFFECTS OF SEVERE ARTERIAL HYPOCAPNIA ON REGIONAL BLOOD-FLOW REGULATION, TISSUE PO2 AND METABOLISM IN THE BRAIN CORTEX OF CATS [J].
GROTE, J ;
ZIMMER, K ;
SCHUBERT, R .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1981, 391 (03) :195-199
[8]   Comparison of changes in cerebral blood flow and cerebral oxygen saturation measured by near infrared spectroscopy (NIRS) after acetazolamide [J].
Holzschuh, M ;
Woertgen, C ;
Metz, C ;
Brawanski, A .
ACTA NEUROCHIRURGICA, 1997, 139 (01) :58-62
[9]   OXYGEN DEPENDENCE OF REDOX STATE OF COPPER IN CYTOCHROME-OXIDASE INVITRO [J].
HOSHI, Y ;
HAZEKI, O ;
TAMURA, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 74 (04) :1622-1627
[10]  
KENNEALY JA, 1980, AM REV RESPIR DIS, V122, P407