Molybdate sensor based on 5,10,15,20-tetraphenylporphyrinatocobalt complex in a PVC matrix

被引:36
作者
Gupta, VK [1 ]
Jain, AK [1 ]
Singh, LP [1 ]
Khurana, U [1 ]
Kumar, P [1 ]
机构
[1] Univ Roorkee, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
sensors; ion-selective electrode; molybdate-selective electrode;
D O I
10.1016/S0003-2670(98)00629-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poly(vinyl chloride) (PVC) based membranes of 5,10,15,20-tetraphenylporphyrinatocobalt (I), incorporating dibutyl phthalate (DBP) in the composition 9:55:36 (I:PVC:DBP) responds to molybdate (MoO42-) over the concentration range 7.6 x 10(-6) - 1.0 x 10(-1) mol l(-1), pH between 4.9 and 11.3, with a Nernstian slope and a fast response time of 15 s. The membrane shows excellent selectivity towards MoO42- ions over a number of other anions and exhibits stable response for more than four months. The sensor can be used in non-aqueous medium with no significant change in the value of slope or working concentration range for the estimation of MoO42- in solutions having upto 25% (v/v) non-aqueous fraction. It was applied for the estimation of molybdenum as molybdate in a sample of molybdenite, a low grade ore. (C) 1999 Elsevier Science B,V. All rights reserved.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 12 条
[1]   A SIMPLIFIED SYNTHESIS FOR MESO-TETRAPHENYLPORPHIN [J].
ADLER, AD ;
LONGO, FR ;
FINARELLI, JD ;
GOLDMACH.J ;
ASSOUR, J ;
KORSAKOF.L .
JOURNAL OF ORGANIC CHEMISTRY, 1967, 32 (02) :476-+
[2]   DETERMINATION AND APPLICATION OF ION-SELECTIVE ELECTRODE MODEL PARAMETERS USING FLOW-INJECTION AND SIMPLEX OPTIMIZATION [J].
DEVITERI, FJS ;
DIAMOND, D .
ANALYST, 1994, 119 (05) :749-758
[3]  
DOROUGH GD, 1951, J AM CHEM SOC, V73, P4314
[4]   Porphyrins as carrier in PVC based membrane potentiometric sensors for nickel(II) [J].
Gupta, VK ;
Jain, AK ;
Singh, LP ;
Khurana, U .
ANALYTICA CHIMICA ACTA, 1997, 355 (01) :33-41
[5]   Macrocycle based membrane sensors for the determination of cobalt(II) ions [J].
Jain, AK ;
Gupta, VK ;
Singh, LP ;
Khurana, U .
ANALYST, 1997, 122 (06) :583-586
[6]   AN ANION-SELECTIVE MEMBRANE-ELECTRODE BASED ON A MIXTURE OF INSOLUBLE LEAD SALTS [J].
LEE, D ;
CHENG, KL .
TALANTA, 1990, 37 (09) :901-904
[7]   POTENTIOMETRIC ESTIMATION OF MOLYBDATE ION WITH A SOLID MEMBRANE-ELECTRODE [J].
MALIK, WU ;
SRIVASTAVA, SK ;
BANSAL, A .
ANALYTICAL CHEMISTRY, 1982, 54 (08) :1399-1402
[8]  
SERGEEV GM, 1983, ZH ANAL KHIM, V38, P1816
[9]   PROPERTIES AND ANALYTICAL APPLICATION OF A NEW MEMBRANE-ELECTRODE SENSITIVE TO MOLYBDENUM(VI) [J].
SHPIGUN, LK ;
ABANINA, EN ;
GALLAI, ZA ;
SHEINA, NM .
TALANTA, 1985, 32 (08) :659-661
[10]   DETERMINATION OF LEAD USING A POLY(VINYL CHLORIDE)-BASED CROWN-ETHER MEMBRANE [J].
SRIVASTAVA, SK ;
GUPTA, VK ;
JAIN, S .
ANALYST, 1995, 120 (02) :495-498