Does UV irradiation affect polymer properties relevant to tissue engineering?

被引:77
作者
Fischbach, C
Tessmar, J
Lucke, A
Schnell, E
Schmeer, G
Blunk, T
Göpferich, A [1 ]
机构
[1] Univ Regensburg, Dept Pharmaceut Technol, D-93040 Regensburg, Germany
[2] Univ Regensburg, Dept Phys & Theoret Chem, D-93040 Regensburg, Germany
关键词
photoelectron spectroscopy; atomic force microscopy; surface structure; morphology; roughness; and topography; biological molecules - proteins; adhesion;
D O I
10.1016/S0039-6028(01)01297-3
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
For most tissue engineering approaches aiming at the repair or generation of living tissues the interaction of cells and polymeric biomaterials is of paramount importance. Prior to contact with cells or tissues, biomaterials have to be sterilized. However, many sterilization procedures such as steam autoclave or heat sterilization are known to strongly affect polymer properties. UV irradiation is used as an alternative sterilization method in many tissue engineering laboratories on a routine basis, however, potential alterations of polymer properties have not been extensively considered, In this study we investigated the effects of UV irradiation on spin-cast films made from biodegradable poly(D,L-lactic acid)-poly(ethylene glycol)-monomethyl ether diblock copolymers (Me.PEG-PLA) which have recently been developed for controlled cell-biomaterial interaction. After 2 h of UV irradiation, which is sufficient for sterilization, no alterations in cell adhesion to polymer films were detected, as demonstrated with 3T3-L1 preadipocytes. This correlated with unchanged film topography and molecular weight distribution. However, extended UV irradiation for 5-24 h elicited drastic responses regarding Me.PEG-PLA polymer properties and interactions with biological elements: Large increases in unspecific protein adsorption and subsequent cell adhesion were observed, Changes in polymer surface properties could be correlated with the observed alterations in cell/protein-polymer interactions. Atomic force microscopy analysis of polymer films revealed a marked "smoothing" of the polymer surface after UV irradiation. Investigations using GPC, H-1-NMR, mass spectrometry, and a PEG-specific colorimetric assay demonstrated that polymer film composition was time-dependently affected by exposure to UV irradiation, i.e., that large amounts of PEG were lost from the copolymer surface. The data indicate that sterilization using UV irradiation for 2 h is an appropriate technique for the recently synthesized Me.PEG-PLA diblock copolymers. However, the study also serves as an example that it is indispensable to control the duration of exposure to UV irradiation for a given biomaterial in order not to compromise polymer properties relevant to tissue engineering purposes. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:333 / 345
页数:13
相关论文
共 25 条
[1]   RESISTANCE OF SELECTED STRAINS OF PSEUDOMONAS-AERUGINOSA TO LOW-INTENSITY ULTRAVIOLET-RADIATION [J].
ABSHIRE, RL ;
DUNTON, H .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1981, 41 (06) :1419-1423
[2]  
BALEUX B, 1972, CR ACAD SCI C CHIM, V274, P1617
[3]   Tetracycline-HCl-loaded poly(DL-lactide-co-glycolide) microspheres prepared by a spray drying technique:: influence of γ-irradiation on radical formation and polymer degradation [J].
Bittner, B ;
Mäder, K ;
Kroll, C ;
Borchert, HH ;
Kissel, T .
JOURNAL OF CONTROLLED RELEASE, 1999, 59 (01) :23-32
[4]  
BOUSQUET J, 1991, CLIN REV ALLERG, V9, P357
[5]   POLYMER SUBSTRATES FOR CONTROLLED BIOLOGICAL INTERACTIONS [J].
CIMA, LG .
JOURNAL OF CELLULAR BIOCHEMISTRY, 1994, 56 (02) :155-161
[6]   Protein stability in controlled-release systems [J].
Fu, K ;
Klibanov, AM ;
Langer, R .
NATURE BIOTECHNOLOGY, 2000, 18 (01) :24-25
[7]   Mechanisms of polymer degradation and erosion [J].
Gopferich, A .
BIOMATERIALS, 1996, 17 (02) :103-114
[8]  
Göpferich A, 1999, J BIOMED MATER RES, V46, P390
[9]   'Stealth' corona-core nanoparticles surface modified by polyethylene glycol (PEG):: influences of the corona (PEG chain length and surface density) and of the core composition on phagocytic uptake and plasma protein adsorption [J].
Gref, R ;
Lück, M ;
Quellec, P ;
Marchand, M ;
Dellacherie, E ;
Harnisch, S ;
Blunk, T ;
Müller, RH .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2000, 18 (3-4) :301-313
[10]   Optimizing the sterilization of PLGA scaffolds for use in tissue engineering [J].
Holy, CE ;
Cheng, C ;
Davies, JE ;
Shoichet, MS .
BIOMATERIALS, 2001, 22 (01) :25-31