Sliding motion modulates stiffness and friction coefficient at the surface of tissue engineered cartilage

被引:44
作者
Grad, S. [1 ]
Loparic, M. [2 ]
Peter, R. [1 ]
Stolz, M. [3 ]
Aebi, U. [2 ]
Alini, M. [1 ]
机构
[1] AO Res Inst Davos, CH-7270 Davos, Switzerland
[2] Univ Basel, Biozentrum, ME Muller Inst Struct Biol, CH-4003 Basel, Switzerland
[3] Univ Southampton, Sch Engn Sci, NCATS, Southampton SO9 5NH, Hants, England
关键词
Articular cartilage; Functional tissue engineering; Atomic force microscopy; Stiffness; Friction; Lubricin; ATOMIC-FORCE MICROSCOPY; BOVINE ARTICULAR-CARTILAGE; SUPERFICIAL ZONE PROTEIN; GENE-EXPRESSION; POLYURETHANE SCAFFOLDS; FUNCTIONAL-PROPERTIES; ELASTIC-MODULUS; SYNOVIAL-FLUID; CHONDROCYTES; INDENTATION;
D O I
10.1016/j.joca.2011.12.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Objective: Functional cartilage tissue engineering aims to generate grafts with a functional surface, similar to that of authentic cartilage. Bioreactors that stimulate cell-scaffold constructs by simulating natural joint movements hold great potential to generate cartilage with adequate surface properties. In this study two methods based on atomic force microscopy (AFM) were applied to obtain information about the quality of engineered graft surfaces. For better understanding of the molecule function relationships, AFM was complemented with immunohistochemistry. Methods: Bovine chondrocytes were seeded into polyurethane scaffolds and subjected to dynamic compression, applied by a ceramic ball, for 1 h daily [loading group 1 (LG1)]. In loading group 2 (LG2), the ball additionally oscillated over the scaffold, generating sliding surface motion. After 3 weeks, the surfaces of the engineered constructs were analyzed by friction force and indentation-type AFM (IT-AFM). Results were complemented and compared to immunohistochemical analyses. Results: The loading type significantly influenced the mechanical and histological outcomes. Constructs of LG2 exhibited lowest friction coefficient and highest micro- and nanostiffness. Collagen type II and aggrecan staining were readily observed in all constructs and appeared to reach deeper areas in loaded (LG1, LG2) compared to unloaded scaffolds. Lubricin was specifically detected at the top surface of LG2. Conclusions: This study proposes a quantitative AFM-based functional analysis at the micrometer- and nanometer scale to evaluate'the quality of cartilage surfaces. Mechanical testing (load-bearing) combined with friction analysis (gliding) can provide important information. Notably, sliding-type biomechanical stimuli may favor (re-)generation and maintenance of functional articular surfaces and support the development of mechanically competent engineered cartilage. (C) 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:288 / 295
页数:8
相关论文
共 58 条
[1]
[Anonymous], 2008, COLLAGEN STRUCTURE M
[2]
Frictional response of bovine articular cartilage under creep loading following proteoglycan digestion with chondroitinase ABC [J].
Basalo, IM ;
Chen, FH ;
Hung, CT ;
Ateshian, GA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (01) :131-134
[3]
Contribution of collagen network features to functional properties of engineered cartilage [J].
Bastiaansen-Jenniskens, Y. M. ;
Koevoet, W. ;
de Bart, A. C. W. ;
van der Linden, J. C. ;
Zuurmond, A. M. ;
Weinans, H. ;
Verhaar, J. A. N. ;
van Osch, G. J. V. M. ;
DeGroot, J. .
OSTEOARTHRITIS AND CARTILAGE, 2008, 16 (03) :359-366
[4]
Articular cartilage: structure, injuries and review of management [J].
Bhosale, Abhijit M. ;
Richardson, James B. .
BRITISH MEDICAL BULLETIN, 2008, 87 (01) :77-95
[5]
Bian LM, 2010, TISSUE ENG PT A, V16, P1781, DOI [10.1089/ten.tea.2009.0482, 10.1089/ten.TEA.2009.0482]
[6]
Mechanical regulation of matrix metalloproteinases [J].
Blain, Emma J. .
FRONTIERS IN BIOSCIENCE-LANDMARK, 2007, 12 :507-527
[7]
Articular cartilage engineering with autologous chondrocyte transplantation -: A review of recent developments [J].
Brittberg, M ;
Peterson, L ;
Sjögren-Jansson, E ;
Tallheden, T ;
Lindahl, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :109-115
[8]
Buckwalter Joseph A, 2005, Instr Course Lect, V54, P465
[9]
Atomic force microscope investigation of the boundary-lubricant layer in articular cartilage [J].
Chan, S. M. T. ;
Neu, C. P. ;
DuRaine, G. ;
Komvopoulos, K. ;
Reddi, A. H. .
OSTEOARTHRITIS AND CARTILAGE, 2010, 18 (07) :956-963
[10]
In situ friction measurement on murine cartilage by atomic force microscopy [J].
Coles, Jeffrey M. ;
Blum, Jason J. ;
Jay, Gregory D. ;
Darling, Eric M. ;
Guilak, Farshid ;
Zauscher, Stefan .
JOURNAL OF BIOMECHANICS, 2008, 41 (03) :541-548