Optimization of injection holes in symmetric and asymmetric scroll compressors with vapor injection

被引:45
作者
Cho, Il Yong [1 ]
Ko, Suk Bin [1 ]
Kim, Yongchan [1 ]
机构
[1] Korea Univ, Dept Mech Engn, Seoul 136713, South Korea
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2012年 / 35卷 / 04期
关键词
Injection; Scroll compressor; Heat pump; Optimization; Performance; LIQUID REFRIGERANT INJECTION; PERFORMANCE; MODEL;
D O I
10.1016/j.ijrefrig.2012.01.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
A simplified numerical model was developed to analyze the optimum injection-hole diameter and angle for symmetric and asymmetric scroll compressors with vapor injection. The present numerical model was validated by comparing the predictions with the measured data for a water-to-water heat pump. The optimized injection-hole angle in the symmetric scroll compressor was much lower than the intuitively observed optimal value of 360 degrees because late injection caused significant backward flow to the injection port. The asymmetric scroll compressor showed a relatively short injection period compared with the symmetric scroll compressor, yielding an unfavorable effect on system performance due to the lower injection mass flow rate. Therefore, in the asymmetric scroll compressor, an increase in the total injection-hole area is a good solution to overcome the performance degradation from short injection periods by increasing the injection-hole diameter and the number of injection holes as well. (C) 2012 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:850 / 860
页数:11
相关论文
共 11 条
[1]  
[Anonymous], 1986, ASHRAE GUID
[2]   Influence of liquid refrigerant injection on the performance of an inverter-driven scroll compressor [J].
Cho, H ;
Chung, JT ;
Kim, Y .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (01) :87-94
[3]   An investigation of the performance of a scroll compressor under liquid refrigerant injection [J].
Dutta, AK ;
Yanagisawa, T ;
Fukuta, M .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (06) :577-587
[4]   Mathematical model of bypass behaviors used in scroll compressor [J].
Liu, Yangguang ;
Hung, Chinghua ;
Chang, Yuchoung .
APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) :1058-1066
[5]  
NIST, 2001, THERM TRANSP PROP RE
[6]   Thermodynamic analysis on the performance of a variable speed scroll compressor with refrigerant injection [J].
Park, YC ;
Kim, Y ;
Cho, H .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2002, 25 (08) :1072-1082
[7]   Design of experimental bench and internal pressure measurement of scroll compressor with refrigerant injection [J].
Wang, Baolong ;
Li, Xianting ;
Shi, Wenxing ;
Yan, Qisen .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (01) :179-186
[8]   Optimization of refrigeration system with gas-injected scroll compressor [J].
Wang, Baolong ;
Shi, Wenxing ;
Han, Linjun ;
Li, Xianting .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (07) :1544-1554
[9]   A general geometrical model of scroll compressors based on discretional initial angles of involute [J].
Wang, BL ;
Li, XT ;
Shi, WX .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (06) :958-966
[10]  
Wang X., 2008, INT REFR AIR COND C, P2119