Kinematic analysis of a multi-segment foot model for research and clinical applications: a repeatability analysis

被引:383
作者
Carson, MC
Harrington, ME [1 ]
Thompson, N
O'Connor, JJ
Theologis, TN
机构
[1] Nuffield Orthopaed Ctr, Oxford Gait Lab, Oxford OX3 7LD, England
[2] Univ Oxford, Oxford Orthopaed Engn Ctr, Oxford, England
[3] Nuffield Orthopaed Ctr, Dept Orthopaed Surg, Oxford OX3 7LD, England
关键词
foot kinematics; gait analysis; repeatability; reliability; stereophotogrammetry;
D O I
10.1016/S0021-9290(01)00101-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
An unbiased understanding of foot kinematics has been difficult to achieve due to the complexity of foot structure and motion. We have developed a protocol for evaluation of foot kinematics during barefoot walking based on a multi-segment foot model. Stereophotogrammetry was used to measure retroreflective markers on three segments of the foot plus the tibia. Repeatability was evaluated between-trial, between-day and between-tester using two subjects and two testers. Subtle patterns and ranges of motion between segments of the foot were consistently detected. We found that repeatability between different days or different testers is primarily subject to variability of marker placement more than inter-tester variability or skin movement. Differences between inter-segment angle curves primarily represent a shift in the absolute value of joint angles from one set of trials to another. In the hallux. variability was greater than desired due to vibration of the marker array used. The method permits objective foot measurement in gait analysis using skin-mounted markers. Quantitative and objective characterisation of the kinematics of the foot during activity is an important area of clinical and research evaluation. With this work we hope to have provided a firm basis for a common protocol for in vivo foot study. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1299 / 1307
页数:9
相关论文
共 20 条
[1]
*AAOS, 1966, JOINT MOT METH MEAS
[2]
Altman DG, 1990, PRACTICAL STAT MED R
[3]
DANDREA S, 1993, P 8 ANN E COAST CLIN, P109
[4]
DELOZIER G, 1991, INT S 3 DIM AN HUM M, P79
[5]
GAGE JR, 1997, CLIN GAIT ANAL FOCUS
[6]
A JOINT COORDINATE SYSTEM FOR THE CLINICAL DESCRIPTION OF 3-DIMENSIONAL MOTIONS - APPLICATION TO THE KNEE [J].
GROOD, ES ;
SUNTAY, WJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02) :136-144
[7]
Jahss M, 1991, DISORDERS FOOT ANKLE
[8]
REPEATABILITY OF KINEMATIC, KINETIC, AND ELECTROMYOGRAPHIC DATA IN NORMAL ADULT GAIT [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME ;
GAINEY, J ;
GORTON, G ;
COCHRAN, GVB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) :849-860
[9]
KAPANDJI IA, 1987, PHYSL JOINTS, V2
[10]
Kidder S M, 1996, IEEE Trans Rehabil Eng, V4, P25, DOI 10.1109/86.486054