Stent thrombosis after sirolimus eluting stent implantation has been reported to occur at six hours to 375 days after the procedure and usually within the two weeks after discontinuation of antiplatelet medication. A case is reported of very late stent thrombosis after 17 months of sirolimus eluting stent implantation and eight months after clopidogrel discontinuation despite aspirin continuation. This case underlines the possible need for long term antiplatelet medication among patients receiving sirolimus eluting stents.
引用
收藏
页数:2
相关论文
共 10 条
[1]  
Cutlip DE, 2001, CIRCULATION, V103, P1967
[2]   Pathological mechanisms of fatal late coronary stent thrombosis in humans [J].
Farb, A ;
Burke, AP ;
Kolodgie, FD ;
Virmani, R .
CIRCULATION, 2003, 108 (14) :1701-1706
[3]   Stent thrombosis after successful sirolimus-eluting stent implantation [J].
Jeremias, A ;
Sylvia, B ;
Bridges, J ;
Kirtane, AJ ;
Bigelow, B ;
Pinto, DS ;
Ho, KKL ;
Cohen, DJ ;
Garcia, LA ;
Cutlip, DE ;
Carrozza, JP .
CIRCULATION, 2004, 109 (16) :1930-1932
[4]   Late stent thrombosis after implantation of a sirolimus-eluting stent [J].
Kerner, A ;
Gruberg, L ;
Kapeliovich, M ;
Grenadier, E .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (04) :505-508
[5]   Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy [J].
McFadden, EP ;
Stabile, E ;
Regar, E ;
Cheneau, E ;
Ong, ATL ;
Kinnaird, T ;
Suddath, WO ;
Weissman, NJ ;
Torguson, R ;
Kent, KM ;
Pichard, AD ;
Satler, LF ;
Waksman, R ;
Serruys, PW .
LANCET, 2004, 364 (9444) :1519-1521
[6]   Incidence of thrombotic stent occlusion during the first three months after Sirolimus-Eluting Stent implantation in 500 consecutive patients [J].
Regar, E ;
Lemos, PA ;
Saia, F ;
Degertekin, M ;
Tanabe, K ;
Lee, CH ;
Arampatzis, CA ;
Hoye, A ;
Sianos, G ;
de Feyter, P ;
van der Giessen, WJ ;
Smits, PC ;
van Domburg, RT ;
Serruys, PW .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (10) :1271-1275
[7]   Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries [J].
vanderGiessen, WJ ;
Lincoff, AM ;
Schwartz, RS ;
vanBeusekom, HMM ;
Serruys, PW ;
Holmes, DR ;
Ellis, SG ;
Topol, EJ .
CIRCULATION, 1996, 94 (07) :1690-1697
[8]   Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent should we be cautious? [J].
Virmani, R ;
Guagliumi, G ;
Farb, A ;
Musumeci, G ;
Grieco, N ;
Motta, T ;
Mihalcsik, L ;
Tespili, M ;
Valsecchi, O ;
Kolodgie, FD .
CIRCULATION, 2004, 109 (06) :701-705
[9]   Mechanism of late in-stent restenosis after implantation of a paclitaxel derivate-eluting polymer stent system in humans [J].
Virmani, R ;
Liistro, F ;
Stankovic, G ;
Di Mario, C ;
Montorfano, M ;
Farb, A ;
Kolodgie, FD ;
Colombo, A .
CIRCULATION, 2002, 106 (21) :2649-2651
[10]   Late coronary stent thrombosis: Early vs. late stent thrombosis in the stent era [J].
Wang, FW ;
Stouffer, GA ;
Waxman, S ;
Uretsky, BF .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 55 (02) :142-147