Perceived fidelity of compressed and reconstructed Radiological images: A preliminary exploration of compression, luminance, and viewing distance

被引:15
作者
Pilgram, TK [1 ]
Slone, RM [1 ]
Muka, E [1 ]
Cox, JR [1 ]
Blaine, GJ [1 ]
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
thorax; radiography; images; compression; fidelity;
D O I
10.1007/BF03178079
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors' goal was to explore the impact of image compression algorithm and ratio, image luminance, and viewing distance on radiologists' perception of reconstructed image fidelity. Five radiologists viewed 16 sets of four hard-copy chest radiographs prepared for secondary interpretation. Each set included one uncompressed, and three compressed and reconstructed images prepared using three different algorithms but the same compression ratio. The sets were prepared using two subjects, four compression ratios (10:1, 20:1, 30:1, 40:1), and two luminance levels (2,400 cd/m(2), standard lightbox illumination, and 200 cd/m(2), simulating a typical CRT display). Readers ranked image quality and evaluated obviousness and clinical importance of differences. Viewing distances for image screening, inspection, and comparison were recorded. At 10:1 compression, the compressed and uncompressed images were nearly indistinguishable; the three algorithms were very similar, and differences were rated "not obvious" and "not important." At higher compression, readers consistently preferred uncompressed images, with notable differences between algorithms. The obviousness and clinical importance of differences were rated higher at lightbox luminance. Viewing distances appeared to be idiosyncratic. Copyright (C) 1998 by W.B. Saunders Company.
引用
收藏
页码:168 / 175
页数:8
相关论文
共 15 条
[1]   THE EFFECT OF IRREVERSIBLE IMAGE COMPRESSION ON DIAGNOSTIC-ACCURACY IN THORACIC IMAGING [J].
ABERLE, DR ;
GLEESON, F ;
SAYRE, JW ;
BROWN, K ;
BATRA, P ;
YOUNG, DA ;
STEWART, BK ;
HO, BKT ;
HUANG, HK .
INVESTIGATIVE RADIOLOGY, 1993, 28 (05) :398-403
[2]   IMAGE DATA-COMPRESSION [J].
BRAMBLE, JM ;
HUANG, HK ;
MURPHY, MD .
INVESTIGATIVE RADIOLOGY, 1988, 23 (10) :707-712
[3]  
BUNGE RE, 1980, FDA US DEPT HHS PUBL, P172
[4]  
Cox JR, 1997, P SOC PHOTO-OPT INS, V3031, P256, DOI 10.1117/12.273903
[5]   Lossy compression using wavelets, block DCT, and lapped orthogonal transforms optimized with a perceptual model [J].
Eckert, MP .
IMAGE DISPLAY - MEDICAL IMAGING 1997, 1997, 3031 :339-350
[6]   APPLICATION OF WAVELET COMPRESSION TO DIGITIZED RADIOGRAPHS [J].
GOLDBERG, MA ;
PIVOVAROV, M ;
MAYOSMITH, WW ;
BHALLA, MP ;
BLICKMAN, JG ;
BRAMSON, RT ;
BOLAND, GWL ;
LLEWELLYN, HJ ;
HALPERN, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :463-468
[7]   SELECTION OF PROCESSING ALGORITHMS FOR DIGITAL IMAGE COMPRESSION - A RANK-ORDER STUDY [J].
HOLBERT, JM ;
STAIGER, M ;
CHANG, TS ;
TOWERS, JD ;
BRITTON, CA .
ACADEMIC RADIOLOGY, 1995, 2 (04) :273-276
[8]   CLINICAL-EVALUATION OF IRREVERSIBLE IMAGE COMPRESSION - ANALYSIS OF CHEST IMAGING WITH COMPUTED RADIOGRAPHY [J].
ISHIGAKI, T ;
SAKUMA, S ;
IKEDA, M ;
ITOH, Y ;
SUZUKI, M ;
IWAI, S .
RADIOLOGY, 1990, 175 (03) :739-743
[9]  
JONES PW, 1995, P SOC PHOTO-OPT INS, V2431, P571, DOI 10.1117/12.207655
[10]  
KOCHER TE, 1991, P SOC PHOTO-OPT INS, V1446, P459, DOI 10.1117/12.45305