Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditure

被引:322
作者
Brage, S
Brage, N
Franks, PW
Ekelund, U
Wong, MY
Andersen, LB
Froberg, K
Wareham, NJ
机构
[1] Odense Univ, Univ So Denmark, Inst Sport Sci & Clin Biomech, DK-5230 Odense, Denmark
[2] Univ Copenhagen, Inst Sport Sci, DK-2200 Copenhagen, Denmark
[3] Univ Cambridge, Inst Publ Hlth, Cambridge CB2 2SR, England
[4] Univ Orebro, Dept Phys Educ & Hlth, S-70182 Orebro, Sweden
[5] Hong Kong Univ Sci & Technol, Dept Math, Kowloon, Hong Kong, Peoples R China
关键词
validity; intensity; epidemiology; calorimetry; movement sensor; activity monitor; energy expenditure; individual calibration;
D O I
10.1152/japplphysiol.00703.2003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The combination of heart rate (HR) monitoring and movement registration may improve measurement precision of physical activity energy expenditure (PAEE). Previous attempts have used either regression methods, which do not take full advantage of synchronized data, or have not used movement data quantitatively. The objective of the study was to assess the precision of branched model estimates of PAEE by utilizing either individual calibration (IC) of HR and accelerometry or corresponding mean group calibration (GC) equations. In 12 men (20.6 - 25.2 kg/m(2)), IC and GC equations for physical activity intensity (PAI) were derived during treadmill walking and running for both HR ( Polar) and hip-acceleration [ Computer Science and Applications (CSA)]. HR and CSA were recorded minute by minute during 22 h of whole body calorimetry and converted into PAI in four different weightings (P1-4) of the HR vs. the CSA (1- P1-4) relationships: if CSA > x, we used the P1 weighting if HR > y, otherwise P-2. Similarly, if CSA less than or equal to x, we used P-3 if HR > z, otherwise P-4. PAEE was calculated for a 12.5-h nonsleeping period as the time integral of PAI. A priori, we assumed P-1 = 1, P-2 = P-3 = 0.5, P-4 = 0, x = 5 counts/min, y = walking/ running transition HR, and z = flex HR. These parameters were also estimated post hoc. Means +/- SD estimation errors of a priori models were - 4.4 +/- 29 and 3.5 +/- 20% for IC and GC, respectively. Corresponding post hoc model errors were - 1.5 +/- 13 and 0.1 +/- 9.8%, respectively. All branched models had lower errors ( P less than or equal to 0.035) than single-measure estimates of CSA ( less than or equal to - 45%) and HR ( greater than or equal to 39%), as well as their nonbranched combination ( greater than or equal to 25.7%). In conclusion, combining HR and CSA by branched modeling improves estimates of PAEE. IC may be less crucial with this modeling technique.
引用
收藏
页码:343 / 351
页数:9
相关论文
共 41 条
  • [1] [Anonymous], 2003, Measurement in Physical Education and Exercise Science, DOI DOI 10.1207/S15327841MPEE0702_
  • [2] Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine
    Atkinson, G
    Nevill, AM
    [J]. SPORTS MEDICINE, 1998, 26 (04) : 217 - 238
  • [3] Validity of four motion sensors in measuring moderate intensity physical activity
    Bassett, DR
    Ainsworth, BE
    Swartz, AM
    Strath, SJ
    O'Brien, WL
    King, GA
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) : S471 - S480
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] Reexamination of validity and reliability of the CSA monitor in walking and running
    Brage, S
    Wedderkopp, N
    Franks, PW
    Andersen, LB
    Froberg, K
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) : 1447 - 1454
  • [6] Influence of step frequency on movement intensity predictions with the CSA accelerometer: A field validation study in children
    Brage, S
    Wedderkopp, N
    Andersen, LB
    Froberg, K
    [J]. PEDIATRIC EXERCISE SCIENCE, 2003, 15 (03) : 277 - 287
  • [7] Consolazio C., 1963, PHYSL MEASUREMENTS M
  • [8] Free-living energy expenditure of adult men assessed by continuous heart-rate monitoring and doubly-labelled water
    Davidson, L
    McNeill, G
    Haggarty, P
    Smith, JS
    Franklin, MF
    [J]. BRITISH JOURNAL OF NUTRITION, 1997, 78 (05) : 695 - 708
  • [9] Is the ArteACC index a valid indicator of free-living physical activity in adolescents?
    Ekelund, U
    Åman, J
    Westerterp, K
    [J]. OBESITY RESEARCH, 2003, 11 (06): : 793 - 801
  • [10] The validity of the Computer Science and Applications activity monitor for use in coronary artery disease patients during level walking
    Ekelund, U
    Tingström, P
    Kamwendo, K
    Krantz, M
    Nylander, E
    Sjöström, M
    Bergdahl, B
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2002, 22 (04) : 248 - 253