PARETO: A novel evolutionary optimization approach to multiobjective IMRT planning

被引:31
作者
Fiege, Jason [1 ]
McCurdy, Boyd [1 ,2 ,3 ]
Potrebko, Peter [4 ]
Champion, Heather [1 ,2 ]
Cull, Andrew [1 ,2 ]
机构
[1] Univ Manitoba, Dept Phys & Astron, Winnipeg, MB R3T 2N2, Canada
[2] CancerCare Manitoba, Div Med Phys, Winnipeg, MB R3E 0V9, Canada
[3] Univ Manitoba, Dept Radiol, Winnipeg, MB R3T 2N2, Canada
[4] Winnipeg Hlth Sci Ctr, Kleysen Inst Adv Med, Winnipeg, MB R3A 1R9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
multiobjective optimization; PARETO; beam orientation optimization; IMRT; MODULATED RADIATION-THERAPY; MULTICRITERIA OPTIMIZATION; ALGORITHM; BEAMS; ORIENTATIONS; EXPLORATION; NAVIGATION; NUMBER; PLANS;
D O I
10.1118/1.3615622
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Purpose: In radiation therapy treatment planning, the clinical objectives of uniform high dose to the planning target volume (PTV) and low dose to the organs-at-risk (OARs) are invariably in conflict, often requiring compromises to be made between them when selecting the best treatment plan for a particular patient. In this work, the authors introduce Pareto-Aware Radiotherapy Evolutionary Treatment Optimization (PARETO), a multiobjective optimization tool to solve for beam angles and fluence patterns in intensity-modulated radiation therapy (IMRT) treatment planning. Methods: pareto is built around a powerful multiobjective genetic algorithm (GA), which allows us to treat the problem of IMRT treatment plan optimization as a combined monolithic problem, where all beam fluence and angle parameters are treated equally during the optimization. We have employed a simple parameterized beam fluence representation with a realistic dose calculation approach, incorporating patient scatter effects, to demonstrate feasibility of the proposed approach on two phantoms. The first phantom is a simple cylindrical phantom containing a target surrounded by three OARs, while the second phantom is more complex and represents a paraspinal patient. Results: pareto results in a large database of Pareto nondominated solutions that represent the necessary trade-offs between objectives. The solution quality was examined for several PTV and OAR fitness functions. The combination of a conformity-based PTV fitness function and a dose-volume histogram (DVH) or equivalent uniform dose (EUD) -based fitness function for the OAR produced relatively uniform and conformal PTV doses, with well-spaced beams. A penalty function added to the fitness functions eliminates hotspots. Comparison of resulting DVHs to those from treatment plans developed with a single-objective fluence optimizer (from a commercial treatment planning system) showed good correlation. Results also indicated that pareto shows promise in optimizing the number of beams. Conclusions: This initial evaluation of the evolutionary optimization software tool pareto for IMRT treatment planning demonstrates feasibility and provides motivation for continued development. Advantages of this approach over current commercial methods for treatment planning are many, including: (1) fully automated optimization that avoids human controlled iterative optimization and potentially improves overall process efficiency, (2) formulation of the problem as a true multiobjective one, which provides an optimized set of Pareto nondominated solutions refined over hundreds of generations and compiled from thousands of parameter sets explored during the run, and (3) rapid exploration of the final nondominated set accomplished by a graphical interface used to select the best treatment option for the patient. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3615622]
引用
收藏
页码:5217 / 5229
页数:13
相关论文
共 35 条
[1]
COLLAPSED CONE CONVOLUTION OF RADIANT ENERGY FOR PHOTON DOSE CALCULATION IN HETEROGENEOUS MEDIA [J].
AHNESJO, A .
MEDICAL PHYSICS, 1989, 16 (04) :577-592
[2]
[Anonymous], 2002, DESIGN INNOVATION
[3]
Multiobjective optimization with a modified simulated annealing algorithm for external beam radiotherapy treatment planning [J].
Aubry, Jean-Francois ;
Beaulieu, Frederic ;
Sevigny, Caroline ;
Beaulieu, Luc ;
Tremblay, Daniel .
MEDICAL PHYSICS, 2006, 33 (12) :4718-4729
[4]
BARAN A, 2010, THESIS U MANITOBA
[5]
A novel approach to multi-criteria inverse planning for IMRT [J].
Breedveld, Sebastiaan ;
Storchi, Pascal R. M. ;
Keijzer, Marleen ;
Heemink, Arnold W. ;
Heijmen, Ben J. M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (20) :6339-6353
[6]
A multiobjective gradient-based dose optimization algorithm for external beam conformal radiotherapy [J].
Cotrutz, C ;
Lahanas, M ;
Kappas, C ;
Baltas, D .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (08) :2161-2175
[7]
Exploration of tradeoffs in intensity-modulated radiotherapy [J].
Craft, D ;
Halabi, T ;
Bortfeld, T .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (24) :5857-5868
[8]
How many plans are needed in an IMRT multi-objective plan database? [J].
Craft, David ;
Bortfeld, Thomas .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11) :2785-2796
[9]
An approach for practical multiobjective IMRT treatment planning [J].
Craft, David ;
Halabi, Tarek ;
Shih, Helen A. ;
Bortfeld, Thomas .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (05) :1600-1607
[10]
Simultaneous navigation of multiple Pareto surfaces, with an application to multicriteria IMRT planning with multiple beam angle configurations [J].
Craft, David ;
Monz, Michael .
MEDICAL PHYSICS, 2010, 37 (02) :736-741