Subcutaneous tissue mechanical behavior is linear and viscoelastic under uniaxial tension

被引:83
作者
Iatridis, JC
Wu, JR
Yandow, JA
Langevin, HM
机构
[1] Univ Vermont, Dept Mech Engn, Burlington, VT 05405 USA
[2] Univ Vermont, Dept Phys, Burlington, VT 05405 USA
[3] Univ Vermont, Dept Neurol, Burlington, VT 05405 USA
关键词
fascia; skin; subcutaneous connective tissue; tensile material properties; viscoelastic;
D O I
10.1080/03008200390244069
中图分类号
Q2 [细胞生物学];
学科分类号
071009 [细胞生物学]; 090102 [作物遗传育种];
摘要
Subcutaneous tissue is part of a bodywide network of "loose" connective tissue including interstitial connective tissues separating muscles and surrounding all nerves and blood vessels. Despite its ubiquitous presence in the body and its potential importance in a variety of therapies utilizing mechanical stretch, as well as normal movement and exercise, very little is known about loose connective tissue's biomechanical behavior. This study aimed to determine elastic and viscoelastic mechanical properties of ex-vivo rat subcutaneous tissue in uniaxial tension with incremental stress relaxation experiments. The elastic response of the tissue was linear, with instantaneous and equilibrium tensile moduli of 4.77 kPa and 2.75 kPa, respectively. Using a 5 parameter Maxwell solid model, material parameters mu(1) = 0.95 +/- 0.24 Ns/m and mu(2) = 8.49 +/- 2.42 Ns/m defined coefficients of viscosity related to time constants tau(1) M = 3.83 +/- 0.15 sec and tau(2) M = 30.15 +/- 3.16 sec, respectively. Using a continuous relaxation function, parameters C = 0.25 +/- 0.12, tau(1C) = 1.86 +/- 0.34 sec, and tau(2C) = 110.40 +/- 25.59 sec defined the magnitude and frequency limits of the relaxation spectrum. This study provides baseline information for the stress-strain behaviors of subcutaneous connective tissue. Our results underscore the differences in mechanical behaviors between loose and high-load bearing connective tissues and suggest that loose connective tissues may function to transmit mechanical signals to and from the abundant fibroblasts, immune, vascular, and neural cells present within these tissues.
引用
收藏
页码:208 / 217
页数:10
相关论文
共 30 条
[1]
Degeneration and aging affect the tensile behavior of human lumbar anulus fibrosus [J].
Acaroglu, ER ;
Iatridis, JC ;
Setton, LA ;
Foster, RJ ;
Mow, VC ;
Weidenbaum, M .
SPINE, 1995, 20 (24) :2690-2701
[2]
Mechanoreception at the cellular level: The detection, interpretation, and diversity of responses to mechanical signals [J].
Banes, AJ ;
Tsuzaki, M ;
Yamamoto, J ;
Fischer, T ;
Brigman, B ;
Brown, T ;
Miller, L .
BIOCHEMISTRY AND CELL BIOLOGY, 1995, 73 (7-8) :349-365
[3]
Darby R., 1976, VISCOELASTIC FLUIDS
[4]
Mechanical properties of the human gastrointestinal tract [J].
Egorov, VI ;
Schastlivtsev, IV ;
Prut, EV ;
Baranov, AO ;
Turusov, RA .
JOURNAL OF BIOMECHANICS, 2002, 35 (10) :1417-1425
[5]
Effects of strain level and proteoglycan depletion on preconditioning and viscoelastic responses of rat dorsal skin [J].
Eshel, H ;
Lanir, Y .
ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (02) :164-172
[6]
Fawcett DW, 1994, TXB HISTOLOGY
[7]
The material properties of the bovine acetabular labrum [J].
Ferguson, SJ ;
Bryant, JT ;
Ito, K .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2001, 19 (05) :887-896
[8]
A COMPARISON OF THE ELASTIC PROPERTIES OF HUMAN CHOROID AND SCLERA [J].
FRIBERG, TR ;
LACE, JW .
EXPERIMENTAL EYE RESEARCH, 1988, 47 (03) :429-436
[9]
Radial tensile properties of the lumbar annulus fibrosus are site and degeneration dependent [J].
Fujita, Y ;
Duncan, NA ;
Lotz, JC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (06) :814-819
[10]
FUNG YC, 1993, BIOMECHANCIS MECH PR