Stability study of carbon graphite covered quartz crystal

被引:19
作者
Kim, JM
Chang, SM
Suda, Y
Muramatsu, H
机构
[1] Dong A Univ, Dept Chem Engn, Pusan 604714, South Korea
[2] R&D Ctr Mitsubishi Pencil, Gunma 375, Japan
[3] Seiko Instrument, Ctr Adv Technol, Matsudo, Chiba 271, Japan
关键词
QCM; QCA; gas sensor; carbon graphite; CGQC;
D O I
10.1016/S0924-4247(98)00232-5
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper shows the properties and the possibilities of carbon graphite-covered quartz crystal as an organic gas-sensing device. The carbon graphite formed on a side of quartz plate was supported by Pt electrodes. The prepared quartz crystals were heat treated for the enhancement of stability in the temperature range from 100 to 450 degrees C. Impedance analysis of the carbon graphite-covered quartz crystal showed a larger admittance value than that of a Lipid coated quartz crystal, which was based on our previous method for detecting gas components. Using the adsorption and desorption responses, the reproducibility and sensitivity are presented for describing the merits of carbon graphite-covered quartz crystal in the detection of organic gas components. The comparison of sensitivity between commercially available alcohol sensor and carbon graphite-covered quartz crystal is provided for a ppm of ethanol injection. These results prove that the carbon graphite-covered quartz crystals are usable as an organic gas sensor and as an analytical device. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:140 / 147
页数:8
相关论文
共 27 条
[1]   MEASUREMENT OF INTERFACIAL PROCESSES AT ELECTRODE SURFACES WITH THE ELECTROCHEMICAL QUARTZ CRYSTAL MICROBALANCE [J].
BUTTRY, DA ;
WARD, MD .
CHEMICAL REVIEWS, 1992, 92 (06) :1355-1379
[2]   Analysis of the phase transition of polymer blends using quartz crystal analyser [J].
Chang, SM ;
Kim, JM ;
Muramatsu, H ;
Ataka, T ;
Cho, WJ ;
Ha, CS .
POLYMER, 1996, 37 (16) :3757-3759
[3]   DETECTION OF ODORANTS USING AN ARRAY OF PIEZOELECTRIC-CRYSTALS AND NEURAL-NETWORK PATTERN-RECOGNITION [J].
CHANG, SM ;
IWASAKI, Y ;
SUZUKI, M ;
TAMIYA, E ;
KARUBE, I ;
MURAMATSU, H .
ANALYTICA CHIMICA ACTA, 1991, 249 (02) :323-329
[4]  
CHOI SA, 1996, SENSOR MATER, V8, P512
[5]   Application of a novel, plastic formed carbon as a precolumn packing material for the liquid chromatographic determination of acetylcholine and choline in biological samples [J].
Ikarashi, Y ;
Blank, CL ;
Suda, Y ;
Kawakubo, T ;
Maruyama, Y .
JOURNAL OF CHROMATOGRAPHY A, 1995, 718 (02) :267-272
[6]  
JONATHAN AS, 1986, ANAL CHEM, V58, P1033
[7]  
KAWAKUBO T, 1995, TANSO, V16, P201
[8]  
KINOSHITA H, 1994, BUNSEKI KAGAKU, V43, P709
[9]   NANOTRIBOLOGY OF A KR MONOLAYER - A QUARTZ-CRYSTAL MICROBALANCE STUDY OF ATOMIC-SCALE FRICTION [J].
KRIM, J ;
SOLINA, DH ;
CHIARELLO, R .
PHYSICAL REVIEW LETTERS, 1991, 66 (02) :181-184
[10]  
KRIM J, 1988, PHYS REV B, V38, P184