A classification of facial wrinkles

被引:252
作者
Lemperle, G
Holmes, RE
Cohen, SR
Lemperle, SM
机构
[1] Univ Calif San Diego, Div Plast Surg, San Diego, CA 92103 USA
[2] FACESplus Inc, San Diego, CA USA
关键词
D O I
10.1097/00006534-200111000-00048
中图分类号
R61 [外科手术学];
学科分类号
摘要
An increasing number of injectable filler materials for facial wrinkles and folds points to the need for objective measurements of their effectiveness. Patient satisfaction is the goal, but proof of the value of a particular product requires objective measurement. A wrinkle assessment scale was developed as a simple tool for use by plastic surgeons, dermatologists, and aesthetic surgeons who want to assess the changes resulting from injecting filler materials in their patients. By correlating the grade of the wrinkle in the reference photographs with the wrinkle in a patient's face, a classification of 0 to 5 is assigned. Reliability of the scale was assessed by "live" judgment of 76 wrinkles by nine observers. The same rating was given to 92.7 percent of all wrinkles. In a second trial, photographs from 130 wrinkles were presented to eight observers who rated 89.4 percent of all wrinkles equally. A significant correlation of 87 percent was found between subjective ratings and objective wrinkle depth measured by profilometry on 40 silicone impressions. Manufacturers, monitors of clinical trials, health authorities, and most important, patients will benefit from objective data on current and new injectable materials.
引用
收藏
页码:1735 / 1750
页数:16
相关论文
共 27 条
[1]   Comparison of two high-energy, pulsed carbon dioxide lasers in the treatment of periorbital rhytides [J].
Alster, TS .
DERMATOLOGIC SURGERY, 1996, 22 (06) :541-545
[2]   Influence of body water distribution on skin thickness: measurements using high-frequency ultrasound [J].
Eisenbeiss, C ;
Welzel, J ;
Eichler, W ;
Klotz, K .
BRITISH JOURNAL OF DERMATOLOGY, 2001, 144 (05) :947-951
[4]   Pulsed carbon dioxide laser resurfacing of photoaged facial skin [J].
Fitzpatrick, RE ;
Goldman, MP ;
Satur, NM ;
Tope, WD .
ARCHIVES OF DERMATOLOGY, 1996, 132 (04) :395-402
[5]  
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
[6]   Aesthetic and anatomic analysis of the aging skin [J].
Glogau, RG .
SEMINARS IN CUTANEOUS MEDICINE AND SURGERY, 1996, 15 (03) :134-138
[7]   OBJECTIVE EVALUATION OF METHODS USED TO TREAT CUTANEOUS WRINKLES [J].
GORMLEY, DE ;
WORTZMAN, MS .
CLINICS IN DERMATOLOGY, 1988, 6 (03) :15-23
[8]   COMPUTER-MODELS AND IMAGES OF THE CUTANEOUS SURFACE [J].
GORMLEY, DE .
DERMATOLOGIC CLINICS, 1986, 4 (04) :641-649
[9]   OPTICAL PROFILOMETRY - AN OBJECTIVE METHOD FOR QUANTIFICATION OF FACIAL WRINKLES [J].
GROVE, GL ;
GROVE, MJ ;
LEYDEN, JJ .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1989, 21 (03) :631-637
[10]   A quantitative method for the assessment of facial rejuvenation: a prospective study investigating the carbon dioxide laser [J].
Grover, R ;
Grobbelaar, AO ;
Morgan, BDG ;
Gault, DT .
BRITISH JOURNAL OF PLASTIC SURGERY, 1998, 51 (01) :8-13