Highly cross-linked polyethylene in cemented THA -: Randomized study of 61 hips

被引:99
作者
Digas, G [1 ]
Kärrholm, J [1 ]
Thanner, J [1 ]
Malchau, H [1 ]
Herberts, P [1 ]
机构
[1] Univ Gothenburg, Sahlgrens Univ Hosp, Inst Surg Sci, Dept Orthopaed, Gothenburg, Sweden
关键词
D O I
10.1097/01.blo.0000096802.78689.45
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Highly cross-linked polyethylene (PE) has been introduced as an alternative bearing material in total hip arthroplasty (THA) because of high wear resistance in laboratory tests but the clinical experience of this material is limited. We evaluated a highly cross-linked PE (warm irradiated adiabatic melting, absorbed dose, 95 kGy) in a randomized study of cemented THAs. Cups of the same design but made of conventionally gamma irradiated PE (absorbed dose, 25-40 kGy) constituted the control group. Sixty-one hips (30 women, 30 men) with a median age of 55 years (range, 35-70 years) were included. All patients received a Spectron stem with 28-mm CoCr head. Radiostereometric examinations with the patient supine or standing were done at regular intervals. Wear was measured with the patient in the supine position from the first postoperative week, whereas examinations done with the patient standing were initiated 3 months after the operation. Dual xray absorptiometry and conventional radiography were used to evaluate the bone mineral density and the radiolucencies around the acetabular component. Fifty-two patients (53 hips; 25 highly cross-linked, 28 control) have been followed up for 2 years. At the 2-year followup, the highly cross-linked cups showed 50% reduction of proximal wear compared with the control group, when the patients were studied standing. When evaluated supine, the difference in proximal wear did not reach significance. The migration of the socket, the relative changes of periprosthetic bone mineral density, and the progression of radiolucencies between the immediately postoperative followup and 2-year followup did not differ. Highly cross-linked PE showed increase resistance to wear. Different mechanical properties of the two types of PE studied did not alter the performance of the cup in terms of fixation, periprosthetic bone loss, and radiographic appearance. However, the followup is short and these results are preliminary.
引用
收藏
页码:126 / 138
页数:13
相关论文
共 44 条
[1]
Baker DA, 1999, J BIOMED MATER RES, V46, P573, DOI 10.1002/(SICI)1097-4636(19990915)46:4<573::AID-JBM16>3.0.CO
[2]
2-A
[3]
IMPROVED CEMENTING TECHNIQUES AND FEMORAL COMPONENT LOOSENING IN YOUNG-PATIENTS WITH HIP-ARTHROPLASTY - A 12-YEAR RADIOGRAPHIC REVIEW [J].
BARRACK, RL ;
MULROY, RD ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :385-389
[4]
THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[5]
Bragdon C R, 1996, Proc Inst Mech Eng H, V210, P157, DOI 10.1243/PIME_PROC_1996_210_408_02
[6]
Experimental assessment of precision and accuracy of radio stereometric analysis for the determination of polyethylene wear in a total hip replacement model [J].
Bragdon, CR ;
Malchau, H ;
Yuan, XH ;
Perinchief, R ;
Kärrholm, J ;
Börlin, N ;
Estok, DM ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (04) :688-695
[7]
ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION [J].
BROOKER, AF ;
BOWERMAN, JW ;
ROBINSON, RA ;
RILEY, LH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) :1629-1632
[8]
Charnley total hip arthroplasty with cement - Minimum twenty-five-year follow-up [J].
Callaghan, JJ ;
Albright, JC ;
Goetz, DD ;
Olejniczak, JP ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (04) :487-497
[9]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[10]
DEVANE PA, 1999, CLIN ORTHOP RELAT R, V369, P59