Radiographic and clinical results of posterior dynamic stabilization for the treatment of multisegment degenerative disc disease with a minimum follow-up of 3 years

被引:82
作者
Yu, Shang-Won [1 ]
Yen, Cheng-Yo [1 ]
Wu, Chin-Hsien [1 ]
Kao, Feng-Chen [1 ]
Kao, Yu-Hsien [1 ]
Tu, Yuan-Kun [1 ]
机构
[1] I Shou Univ, E Da Hosp, Dept Orthoped Surg, Yan Chau Shiang 824, Kaohsiung Count, Taiwan
关键词
Dynamic stabilization; Dynesys; Lumbar spine; Posterior lumbar fusion; Multisegment disease; ADJACENT-SEGMENT DEGENERATION; LUMBAR SPINAL STENOSIS; SYSTEM; FUSION; NEUTRALIZATION; DECOMPRESSION; EXPERIENCE; SPONDYLOLISTHESIS; INSTRUMENTATION; SCREW;
D O I
10.1007/s00402-012-1460-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
This study aims to compare radiographic and clinical outcomes of Dynesys and posterior lumbar interbody fusion (PLIF) for the treatment of multisegment disease. Thirty-five consecutive patients who received Dynesys implantation at three levels from L1 to S1 from November 2006 to July 2007 were studied. A retrospective analysis of the medical records of 25 patients with the same indications who received 3-level PLIF (L1-S1) was also conducted. Radiographic and clinical outcomes between the groups were compared. All patients included in the analysis completed 3-year follow-up. Dynesys stabilization resulted in higher preservation of motion at the operative levels, as well as total range of motion from L1 to S1. A decrease of anterior disc height was seen in the Dynesys group and an increase was seen in the PLIF group. An increase in posterior disc height was noted in both groups; however, was greater in the PLIF group at 3 years. The Dynesys group showed a greater improvement in Oswestry Disability Index and visual analogue scale back pain scores at 3 years postoperatively. There were no differences in complications between the two groups. In conclusion, Dynesys is an acceptable alternative to PLIF for the treatment of multisegment lumbar disease.
引用
收藏
页码:583 / 589
页数:7
相关论文
共 31 条
[1]
The Dynesys lumbar spinal stabilization system - A preliminary report on positional magnetic resonance imaging findings [J].
Beastall, James ;
Karadimas, Efthimios ;
Siddiqui, Manal ;
Nicol, Malcolm ;
Hughes, Justin ;
Smith, Francis ;
Wardlaw, Douglas .
SPINE, 2007, 32 (06) :685-690
[2]
Bordes-Monmeneu M, 2005, NEUROCIRUGIA, V16, P499
[3]
Immediate biomechanical effects of lumbar posterior dynamic stabilization above a circumferential fusion [J].
Cheng, Boyle C. ;
Gordon, Jeff ;
Cheng, Joseph ;
Welch, William C. .
SPINE, 2007, 32 (23) :2551-2557
[4]
Adjacent segment degeneration after lumbar spinal posterolateral fusion with instrumentation in elderly patients [J].
Chou, WY ;
Hsu, CJ ;
Chang, WN ;
Wong, CY .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (01) :39-43
[5]
Inter-observer reliability of detecting Dynesys pedicle screw using plain X-rays: a study on 50 post-operative patients [J].
Dakhil-Jerew, Fras ;
Jadeja, H. ;
Cohen, A. ;
Shepperd, J. A. N. .
EUROPEAN SPINE JOURNAL, 2009, 18 (10) :1486-1493
[6]
How does spinal canal decompression and dorsal stabilization affect segmental mobility? A biomechanical study [J].
Delank, Karl-Stefan ;
Gercek, Erol ;
Kuhn, Sebastian ;
Hartmann, Frank ;
Hely, H. ;
Roellinghoff, Marc ;
Rothschild, M. A. ;
Stuetzer, H. ;
Sobottke, Rolf ;
Eysel, Peer .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (02) :285-292
[7]
Dynesys&REG
[8]
Dynamic Stabilization System, DYN DYN STAB SYST DY
[9]
Clinical experience with the Dynesys semirigid fixation system for the lumbar spine - Surgical and patient-oriented outcome in 50 cases after an average of 2 years [J].
Grob, D ;
Benini, A ;
Junge, A ;
Mannion, AF .
SPINE, 2005, 30 (03) :324-331
[10]
Comparisons of Outcomes After Single or Multilevel Dynamic Stabilization: Effects on Adjacent Segment [J].
Kim, Chi Heon ;
Chung, Chun Kee ;
Jahng, Tae-Ahn .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2011, 24 (01) :60-67