Changes in MRI signal intensity during hypercapnic challenge under conscious and anesthetized conditions

被引:78
作者
Brevard, ME [1 ]
Duong, TQ [1 ]
King, JA [1 ]
Ferris, CF [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Psychiat, Ctr Comparat Neuroimaging, Worcester, MA 01655 USA
关键词
functional magnetic resonance imaging; vascular reactivity; bold signal intensity; regional cerebral blood flow;
D O I
10.1016/S0730-725X(03)00204-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Most functional magnetic resonance imaging (fMRI) studies in animals are conducted under anesthesia to minimize motion artifacts. However, methods and techniques have been developed recently for imaging fully conscious rats. Functional MRI studies on conscious animals report enhanced BOLD signal changes as compared to the anesthetized condition. In this study, rats were exposed to different concentrations of carbon dioxide (CO2) while conscious and anesthetized to test whether cerebrovascular reactivity may be contributing to these enhanced BOLD signal changes. Hypercapnia produced significantly greater increases in MRI signal intensity in fully conscious animals (6.7-13.3% changes) as when anesthetized with 1% isoflurane (3.2-4.9% changes). In addition, the response to hypercapnia was more immediate in the conscious condition (< 30s) with signal risetimes twice as fast as in the anesthetized state (60s). Both cortical and subcortical brain regions showed a robust, dose- dependent increase in MRI signal intensity with hypercapnic challenge while the animals were conscious but little or no change when anesthetized. Baseline variations in MRI signal were higher while animals were conscious but this was off set by greater signal intensity changes leading to a greater contrast-to-noise ratio, 13.1 in conscious animals, as compared to 8.0 in the anesthetized condition. In summary, cerebral vasculature appears to be more sensitive to hypercapnic challenge in the conscious condition resulting in enhanced T2* MRI signal intensity and the potential for better BOLD signal changes during functional imaging. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:995 / 1001
页数:7
相关论文
共 42 条
[1]   Functional MRI studies in awake rhesus monkeys: methodological and analytical strategies [J].
Andersen, AH ;
Zhang, ZM ;
Barber, T ;
Rayens, WS ;
Zhang, JL ;
Grondin, R ;
Hardy, P ;
Gerhardt, GA ;
Gash, DM .
JOURNAL OF NEUROSCIENCE METHODS, 2002, 118 (02) :141-152
[2]  
BIM RM, 1998, MAGN RESON MED, V40, P55
[3]  
BONVENTO G, 1994, J CEREB BLOOD FLOW M
[4]  
BREVARD ME, 2001, P INT SOC MAG RES ME, P676
[5]  
DALY MDB, 1979, LANCET, V1, P764
[6]   Enhancing fMRI contrast in awake-behaving primates using intravascular magnetite dextran nanopartieles [J].
Dubowitz, DJ ;
Bernheim, KA ;
Chen, DY ;
Bradley, WG ;
Andersen, RA .
NEUROREPORT, 2001, 12 (11) :2335-2340
[7]  
EGER EI, 1981, ANESTHESIOLOGY, V55, P559, DOI 10.1097/00000542-198111000-00014
[8]   ADENOSINE AND THE ACID-BASE STATE OF VASCULAR SMOOTH-MUSCLE [J].
FENTON, RA ;
RUBIO, R ;
BERNE, RM .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 51 (01) :179-184
[9]   Functional imaging of brain activity in conscious monkeys responding to sexually arousing cues [J].
Ferris, CF ;
Snowdon, CT ;
King, JA ;
Duong, TQ ;
Ziegler, TE ;
Ugurbil, K ;
Ludwig, R ;
Schultz-Darken, NJ ;
Wu, ZJ ;
Olson, DP ;
Sullivan, JM ;
Tannenbaum, PL ;
Vaughan, JT .
NEUROREPORT, 2001, 12 (10) :2231-2236
[10]  
FLECKNELL PA, 1992, EXPT SURG TECHNIQUES