Deterioration of bone quality by long-term magnetic field with extremely low frequency in rats

被引:30
作者
Gurgul, Serkan [1 ]
Erdal, Nurten [1 ]
Yilmaz, S. Necat [2 ]
Yildiz, Altan [3 ]
Ankarali, Handan [4 ]
机构
[1] Mersin Univ, Fac Med, Dept Biophys, TR-33169 Mersin, Turkey
[2] Mersin Univ, Fac Med, Dept Histol & Embryol, TR-33169 Mersin, Turkey
[3] Mersin Univ, Fac Med, Dept Radiodiagnost, TR-33169 Mersin, Turkey
[4] Karaelmas Univ, Fac Med, Dept Biostat, TR-67600 Zonguldak, Turkey
关键词
bone biomechanics; bone quality; DEXA; electromagnetic field;
D O I
10.1016/j.bone.2007.08.040
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
The aim of our study was to investigate the effects of long-term (45 days) magnetic field (50 Hz, 1 mT; MF) on femur biomechanical parameters of rats. Bone mineral density (BMD) and histological investigation were also evaluated. For this purpose, twenty-four 8-week-old, Wistar-Albino female and male rats were assigned randomly to female control (FC) and MF-exposed rats (F-MF); male control (MC) and MF-exposed rats (M-MF). BMD was measured by dual-energy X-ray absorptiometry. Cross-sectional area of the femoral shaft was evaluated by computerized tomography. Biomechanical measurements were performed at the mid-diaphysis of the left femur with tensile test. Maximum load, displacement, stiffness, energy absorption capacity (structural properties); ultimate stress, ultimate strain, elastic modulus and toughness (material properties) were calculated. Diaphysial cortical bone thickness was measured by using histological method from the right femur. In respect to the cortical thickness of the rats' femurs, there was statistically significant interaction between the gender and group (P<0.05), while the BMD and cortical area were not (P>0.05). The BMD, cortical thickness and area values of the femurs of MF-exposed rats (F-MF, M-MF) were significantly decreased in comparison to that of the controls (FC, MC) (P<0.05). There were no statistically significant differences between the control and the W-exposed rats in respect to the femur length (P>0.05). There were no statistically significant interaction between the gender and group with regard to the maximum load, displacement, stiffness, ultimate stress, ultimate strain, elastic modulus and toughness endpoints, while the energy absorption capacity was significant (P<0.05). Maximum load, displacement and stiffness values of MF-exposed rats were significantly decreased compared to that of the controls (P<0.05). Femurs of M-MF rats had less absorbed energy than that in controls (P<0.05). Ultimate stress and elastic modulus parameters were significantly decreased in MF-exposed rats in comparison to that of the controls (P<0.05). Ultimate strain was higher in MF-exposed rats than that in controls (P>0.05). The mean of toughness was decreased in MF-exposed rats compared to that of the controls (P>0.05). In conclusion, the bone quality of rats is decreased by magnetic field exposure. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:74 / 80
页数:7
相关论文
共 32 条
[1]
ACCELERATION OF FRACTURE REPAIR BY ELECTROMAGNETIC-FIELDS - SURGICALLY NONINVASIVE METHOD [J].
BASSETT, CAL ;
PAWLUK, RJ ;
PILLA, AA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1974, 238 (OCT11) :242-262
[2]
Boyce BF, 1999, LAB INVEST, V79, P83
[3]
FRACTURE-HEALING IN THE RABBIT FIBULA WHEN SUBJECTED TO VARIOUS CAPACITIVELY COUPLED ELECTRICAL FIELDS [J].
BRIGHTON, CT ;
HOZACK, WJ ;
BRAGER, MD ;
WINDSOR, RE ;
POLLACK, SR ;
VRESLOVIC, EJ ;
KOTWICK, JE .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (03) :331-340
[4]
TREATMENT OF SCIATIC DENERVATION DISUSE OSTEOPOROSIS IN THE RAT TIBIA WITH CAPACITIVELY COUPLED ELECTRICAL-STIMULATION - DOSE-RESPONSE AND DUTY CYCLE [J].
BRIGHTON, CT ;
TADDUNI, GT ;
POLLACK, SR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1022-1028
[5]
The contribution of the organic matrix to bone's material properties [J].
Burr, DB .
BONE, 2002, 31 (01) :8-11
[6]
Pulsed electromagnetic fields stimulation affects osteoclast formation by modulation of osteoprotegerin, RANK ligand and macrophage colony-stimulating factor [J].
Chang, K ;
Chang, WHS ;
Huang, S ;
Huang, S ;
Shih, C .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (06) :1308-1314
[7]
Low-exposure cadmium is more toxic on osteoporotic rat femoral bone: Mechanical, biochemical, and histopathological evaluation [J].
Comelekoglu, Ulku ;
Yalin, Serap ;
Bagis, Selda ;
Ogenler, Oya ;
Sahin, N. Ozlen ;
Yildiz, Altan ;
Coskun, Banu ;
Hatungil, Rezan ;
Turac, Aysegul .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2007, 66 (02) :267-271
[8]
NON-INVASIVE TREATMENT OF UNUNITED FRACTURES OF THE TIBIA USING ELECTRICAL-STIMULATION [J].
DEHAAS, WG ;
WATSON, J ;
MORRISON, DM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1980, 62 (04) :465-470
[9]
Effects of pulsed electromagnetic field (PEMF) stimulation on bone tissue like formation are dependent on the maturation stages of the osteoblasts [J].
Diniz, P ;
Shomura, K ;
Soejima, K ;
Ito, G .
BIOELECTROMAGNETICS, 2002, 23 (05) :398-405
[10]
TIME-VARYING MAGNETIC-FIELDS - EFFECTS OF ORIENTATION ON CHONDROCYTE PROLIFERATION [J].
ELLIOTT, JP ;
SMITH, RL ;
BLOCK, CA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (02) :259-264