Analytical study of the effects of the clogging of a mechanical precipitator unit in air preheaters in a high-performance thermoelectric power plant based on available data

被引:10
作者
Blanco, J. M. [1 ]
Pena, F. [1 ]
机构
[1] Univ Basque Country, EHU, Escuela Tecn Super Ingn, Dept Maquinas & Motores Term, Bilbao 48013, Spain
来源
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME | 2008年 / 130卷 / 02期
关键词
thermoelectric power plant; precipitator; exhaust gases; ashes; hoppers; conduit clogging;
D O I
10.1115/1.2795771
中图分类号
TH [机械、仪表工业];
学科分类号
0802 [机械工程];
摘要
Following a detailed study of two of the mechanical precipitators in the air preheaters of a thermoelectric power plant, a large amount of ash that was deposited on one of the inlet conduits was observed, obstructing the incoming gas flow. A comparison of the available data for the two most recent hopper cleaning operations revealed that, on the one hand, the amount of ash collected by the clogged precipitator (A) was significantly less than that collected by the other (B) and, on the other hand, the temperature of the ash in the former was noticeably lower than in the latter Prior to the cleaning of the conduits, a certain amount of damage was caused to the boiler dome, which meant that subsequent cleaning required the use of a hydrolazer where it was noted that inlet pressures were very high. All of this indicated that the cause of the clogging was not physical. This paper provides a comprehensive analytical analysis that explains what happened, as well as resolving the situation.
引用
收藏
页数:7
相关论文
共 32 条
[1]
Turbulence structure in boundary layers over different types of surface roughness [J].
Antonia, R ;
Krogstad, PÅ .
FLUID DYNAMICS RESEARCH, 2001, 28 (02) :139-157
[2]
ATHEY DR, 1986, P INT CTR HEAT MASS, P73
[3]
Baukal C.E., 2000, HEAT TRANSFER IND CO
[4]
Bejan Adrian., 1995, THERMAL DESIGN OPTIM
[5]
Comparative analysis of CO2 and SO2 emissions between combined and conventional cycles with natural gas and fuel oil consumption over the Spanish thermal power plants [J].
Blanco, JM ;
Mendía, F ;
Peña, F .
FUEL, 2006, 85 (09) :1280-1285
[6]
Physical properties of a LPG flame with high-temperature air on a regenerative burner [J].
Blasiak, W ;
Yang, WH ;
Rafidi, N .
COMBUSTION AND FLAME, 2004, 136 (04) :567-569
[7]
CHAPMAN AJ, 1968, HEAT TRANSFER
[8]
GENERAL EXPRESSION FOR CORRELATION OF RATES OF TRANSFER AND OTHER PHENOMENA [J].
CHURCHILL, SW ;
USAGI, R .
AICHE JOURNAL, 1972, 18 (06) :1121-+
[9]
COTTA RM, 1986, INT J HEAT MASS TRAN, V30, P2073
[10]
DIMENSIONAL ANALYSIS AND THE PI-THEOREM [J].
CURTIS, WD ;
LOGAN, JD ;
PARKER, WA .
LINEAR ALGEBRA AND ITS APPLICATIONS, 1982, 47 (OCT) :117-126