Microsecond-pulsed glow discharge time-of-flight mass spectrometry: Analytical advantages

被引:51
作者
Hang, W
Baker, C
Smith, BW
Winefordner, JD
Harrison, WW
机构
[1] Department of Chemistry, University of Florida, Gainesville
关键词
glow discharge; pulsed glow discharge; time-of-flight mass spectrometry; atomic mass spectrometry;
D O I
10.1039/a604454i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microsecond-pulsed glow discharge time-of-flight mass spectrometer was constructed and evaluated for elemental analysis. Mass spectra from the instrument show significant advantages, including higher signal-to-noise ratios than those of a de glow discharge source. Important temporal advantages result from the pulsed discharge and pulsed mass analyser. Mass discrimination among different elements is very small. The instrument currently has a resolving power of 360 in linear mode and 1600 in reflectron mode (full width at half maximum). Present detection limits are at the low ppm level, limited primarily by the detection and data acquisition system. Because the detector is easily saturated, the present data acquisition system has limited dynamic range and sensitivity. Possibilities exist to overcome this constraint.
引用
收藏
页码:143 / 149
页数:7
相关论文
共 16 条
[1]  
ASTON FW, 1924, ISOTOPES
[2]   INSTRUMENTAL SYSTEM FOR MULTIDIMENSIONAL SPECTROSCOPIC CHARACTERIZATION OF A RADIO-FREQUENCY BOOSTED, PULSED HOLLOW-CATHODE LAMP [J].
FARNSWORTH, PB ;
WALTERS, JP .
ANALYTICAL CHEMISTRY, 1982, 54 (06) :885-890
[3]   Microsecond pulsed glow discharge as an analytical spectroscopic source [J].
Hang, W ;
Walden, WO ;
Harrison, WW .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1148-1152
[4]   MICROSECOND PULSED GLOW-DISCHARGE TIME-OF-FLIGHT MASS-SPECTROMETER [J].
HANG, W ;
YANG, PY ;
WANG, XR ;
YANG, CL ;
SU, YX ;
HUANG, BL .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1994, 8 (08) :590-594
[5]   GLOW-DISCHARGE - CONSIDERATIONS AS A VERSATILE ANALYTICAL SOURCE - PLENARY LECTURE [J].
HARRISON, WW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :75-79
[6]   Pulsed glow discharge time-of-flight mass spectrometry [J].
Harrison, WW ;
Hang, W .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :835-840
[7]   RADIO-FREQUENCY-POWERED PLANAR-MAGNETRON GLOW-DISCHARGE AS A SOURCE FOR TIME-OF-PLIGHT ELEMENTAL MASS-SPECTROMETRY [J].
HEINTZ, MJ ;
MYERS, DP ;
MAHONEY, PP ;
LI, GQ ;
HIEFTJE, GM .
APPLIED SPECTROSCOPY, 1995, 49 (07) :945-954
[8]   LASER RESONANCE IONIZATION IN A GLOW-DISCHARGE [J].
HESS, KR ;
HARRISON, WW .
ANALYTICAL CHEMISTRY, 1986, 58 (08) :1696-1702
[9]  
HUANG Ben-li, 1991, CHINESE J ANAL CHEM, V19, P259
[10]  
MAHONEY PP, 1996, 1996 WINT C PLASM SP