Three-dimensional surface characterization for orthopaedic joint prostheses

被引:39
作者
Jiang, XQ [1 ]
Blunt, L [1 ]
Stout, KJ [1 ]
机构
[1] Univ Huddersfield, Sch Engn, Ctr Ultra Precis Engn, Huddersfield HD1 3DH, W Yorkshire, England
关键词
three-dimensional surface topography; orthopaedic joint prostheses; wavelet analysis; characterization techniques;
D O I
10.1243/0954411991534807
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study attempts to investigate a range of 'better' methods for the characterization of the three-dimensional (3D) surface topography of orthopaedic joint prostheses. In this paper, a new characterization tool for the comprehensive identification and evaluation of functional features of these surface topographies is presented. For identification, the surface topography is investigated in a space-scale space, by employing wavelet analysis. The roughness, waviness and form involved in surface topography are consequently separated and recovered respectively. The multiscalar topographical features are identified and captured. The errors caused as a consequence of three-dimensional measurement methods can be reduced. After identification, the three-dimensional surface assessment techniques previously reported by Stout and co-workers are used for the quantitative evaluation of various surface roughness features of the orthopaedic joint prostheses. Moreover, the functional properties, such as bearing area, material volume and void volume which are significantly effected by large peaks, pits and scratches are studied and the location of isolated peaks, pits and scratches in the different scales is also clearly characterized. In this work, measurement of the femoral heads and acetabular cups is carried out to demonstrate the applicability of the characterization technique for the three-dimensional surface topography of orthopaedic joint prostheses.
引用
收藏
页码:49 / 68
页数:20
相关论文
共 29 条
[1]  
[Anonymous], 1996, 72062 ISO
[2]   THE EFFECTS OF HARDNESS AND SURFACE QUALITY OF METAL TAPERS ON THE FRACTURE LOAD OF CERAMIC BALL HEADS IN HIP ENDOPROSTHESES [J].
BACHNICK, M ;
HASENPUSCH, M ;
RICHTER, H ;
BOENICK, U .
BIOMEDIZINISCHE TECHNIK, 1994, 39 (12) :302-306
[3]  
BAUER TW, 1994, CLIN ORTHOP RELAT R, P11
[4]  
*BRIT STAND I, 1990, 7251 BS BRIT STAND I
[5]   MULTISCALE ANALYSIS OF ENGINEERING SURFACES [J].
CHEN, X ;
RAJA, J ;
SIMANAPALLI, S .
INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 1995, 35 (02) :231-238
[6]  
Chui C.K., 1992, An introduction to wavelets, V1, DOI DOI 10.1109/99.388960
[7]   THE WAVELET TRANSFORM, TIME-FREQUENCY LOCALIZATION AND SIGNAL ANALYSIS [J].
DAUBECHIES, I .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1990, 36 (05) :961-1005
[8]   ORTHONORMAL BASES OF COMPACTLY SUPPORTED WAVELETS [J].
DAUBECHIES, I .
COMMUNICATIONS ON PURE AND APPLIED MATHEMATICS, 1988, 41 (07) :909-996
[9]  
DAUBECHIES I, 1992, LECT WAVELETS
[10]   COMPARATIVE-STUDY OF THE WEAR OF UHMWPE WITH ZIRCONIA CERAMIC AND STAINLESS-STEEL FEMORAL HEADS IN ARTIFICIAL HIP JOINTS [J].
DERBYSHIRE, B ;
FISHER, J ;
DOWSON, D ;
HARDAKER, C ;
BRUMMITT, K .
MEDICAL ENGINEERING & PHYSICS, 1994, 16 (03) :229-236