Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise

被引:308
作者
Hsieh, J [1 ]
机构
[1] GE Co, Med Syst, Appl Sci Lab, Milwaukee, WI 53201 USA
关键词
computed tomography; x-ray photon starvation; streak artifact; adaptive filtering;
D O I
10.1118/1.598410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The quality of a computed tomography (CT) image is often degraded by streaking artifacts resulting from excessive x-ray quantum noise. Often, a patient has to be rescanned at a higher technique or at a larger slice thickness in order to obtain an acceptable image for diagnosis. This results in a higher dose to the patient, a degraded cross plane resolution, or a reduced patient throughput. In this paper, we propose an adaptive filtering approach in Radon space based on the local statistical properties of the CT projections. We first model the noise characteristics of a projection sample undergoing important preprocessing steps. A filter is then designed such that its parameters are dynamically adjusted to adapt to the local noise characteristics. Because of the adaptive nature of the filter, a proper balance between streak artifact suppression and spatial resolution preservation is achieved. Phantom and clinical studies have been conducted to evaluate the robustness of our approach. Results demonstrate that the adaptive filtering approach is effective in reducing or eliminating quantum noise induced artifacts in CT. At the same time, the impact on the spatial resolution is kept at a low level. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)00311-3].
引用
收藏
页码:2139 / 2147
页数:9
相关论文
共 19 条
[1]   ALPHA-TRIMMED MEANS AND THEIR RELATIONSHIP TO MEDIAN FILTERS [J].
BEDNAR, JB ;
WATT, TL .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1984, 32 (01) :145-153
[2]   STREAKING IN MEDIAN FILTERED IMAGES [J].
BOVIK, AC .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1987, 35 (04) :493-503
[3]   Respiratory compensation in projection imaging using a magnification and displacement model [J].
Crawford, CR ;
King, KF ;
Ritchie, CJ ;
Godwin, JD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (03) :327-332
[4]   NON-LINEAR PARTIAL VOLUME ARTIFACTS IN X-RAY COMPUTED-TOMOGRAPHY [J].
GLOVER, GH ;
PELC, NJ .
MEDICAL PHYSICS, 1980, 7 (03) :238-248
[5]  
HSIEH J, 1994, P SOC PHOTO-OPT INS, V2298, P662, DOI 10.1117/12.186581
[6]  
Hsieh J, 1997, RADIOLOGY, V205, P319
[7]  
Hsieh J, 1996, INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, PROCEEDINGS - VOL III, P567, DOI 10.1109/ICIP.1996.560558
[8]  
HSIEH J, 1994, P SOC PHOTO-OPT INS, V2299, P316, DOI 10.1117/12.179262
[9]  
HSIEH J, 1992, P SOC PHOTO-OPT INS, V1652, P175, DOI 10.1117/12.59424
[10]  
HSIEH J, 1995, MED CT ULTRASOUND CU