Pilot study comparing the photoelastic stress distribution for four endodontic post systems

被引:13
作者
Cohen, BI [1 ]
Condos, S [1 ]
Musikant, BL [1 ]
Deutsch, AS [1 ]
机构
[1] ESSENTIAL DENT LABS, S HACKENSACK, NJ USA
关键词
D O I
10.1046/j.1365-2842.1996.d01-180.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This pilot study compared stress distribution using photoelastic blocks for both vertical loading and oblique loading (26 degrees angle) for four groups of post systems (Flexi-Post(R), Flexi-Flange(R), ParaPost(R) and AccessPost(R) dowels). For each group, three test blocks of photoelastic material were prepared with simulated endodontic canals, and the specimens were then photographed. Minimal stresses were observed for all the posts after cementation in the unloaded state. Stress distribution for the Flexi-Post, Flexi-Flange and AccessPost were favourable under vertical loading 134 N and oblique loadings of 89 N and 134 N. Stress patterns were symmetric over the entire length of these posts. Stress distribution for the ParaPost under vertical loading at 134 N generated stress patterns that were asymmetric with concentration of stresses apically compared to coronally. Stress distribution for the ParaPost during oblique loadings of 89 N and 134 N were asymmetric with stress concentrated apically as compared to coronally. Stress distribution for the Flexi-Post, Flexi-Flange and AccessPost were all favourable under loading conditions studied.
引用
收藏
页码:679 / 685
页数:7
相关论文
共 21 条
[1]  
BROWN JD, 1987, OPER DENT, V12, P15
[2]   THE RESISTANCE TO TENSILE, COMPRESSION, AND TORSIONAL FORCES PROVIDED BY 4 POST SYSTEMS [J].
BURGESS, JO ;
SUMMITT, JB ;
ROBBINS, JW .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (06) :899-903
[3]   STRESS-DISTRIBUTION SURROUNDING ENDODONTIC POSTS [J].
BURNS, DA ;
KRAUSE, WR ;
DOUGLAS, HB ;
BURNS, DR .
JOURNAL OF PROSTHETIC DENTISTRY, 1990, 64 (04) :412-418
[4]   COMPARISON OF THE RETENTION OF ENDODONTIC POSTS AFTER PREPARATION WITH EDTA [J].
BURNS, DR ;
DOUGLAS, HB ;
MOON, PC .
JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (03) :262-266
[5]  
Cohen B I, 1993, J Prosthodont, V2, P28, DOI 10.1111/j.1532-849X.1993.tb00378.x
[6]   COMPARISON OF THE RETENTIVE PROPERTIES OF 2 HOLLOW-TUBE POST SYSTEMS TO THOSE OF A SOLID POST DESIGN [J].
COHEN, BI ;
MUSIKANT, BL ;
DEUTSCH, AS .
JOURNAL OF PROSTHETIC DENTISTRY, 1993, 70 (03) :234-238
[7]   COMPARISON OF RETENTIVE PROPERTIES OF 4 POST SYSTEMS [J].
COHEN, BI ;
MUSIKANT, BL ;
DEUTSCH, AS .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (02) :264-268
[8]   RETENTION PROPERTIES OF A SPLIT-SHAFT THREADED POST - CUT AT DIFFERENT APICAL LENGTHS [J].
COHEN, BI ;
CONDOS, S ;
MUSIKANT, BL ;
DEUTSCH, AS .
JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (06) :894-898
[9]   RETENTION AND STRESS-DISTRIBUTION OF TAPERED-END ENDODONTIC POSTS [J].
COONEY, JP ;
CAPUTO, AA ;
TRABERT, KC .
JOURNAL OF PROSTHETIC DENTISTRY, 1986, 55 (05) :540-546
[10]   RETENTIVE PROPERTIES OF A NEW POST AND CORE SYSTEM [J].
DEUTSCH, AS ;
MUSIKANT, BL ;
CAVALLARI, J ;
BERNARDI, S .
JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (01) :12-14