Methodological issues on the use of urinary alpha-1-microglobuline in epidemiological studies

被引:28
作者
Andersson, Lena [1 ]
Haraldsson, Borje [2 ]
Johansson, Caroline [1 ]
Barregard, Lars [1 ]
机构
[1] Univ Gothenburg, Sahlgrenska Univ Hosp & Acad, Dept Occupat & Environm Med, S-40530 Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrenska Univ Hosp & Acad, Dept Mol & Clin Med, S-40530 Gothenburg, Sweden
关键词
alpha-1-microglobulin; diurnal; protein HC; urine sampling; variability;
D O I
10.1093/ndt/gfm729
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 [基础医学]; 1002 [临床医学]; 100602 [中西医结合临床];
摘要
Background. Alpha-1-microglobulin (A1M) is a low molecular weight protein that can be measured in urine and used as a marker for tubular function, assuming that the normal variability within and between individuals is known. The aims of this study were to investigate this variability, to find the optimal way of sampling and quantifying A1M in spot urine samples to reflect the 24 h excretion and to examine storage stability. Method. Timed urine specimens were collected from 29 healthy volunteers at fixed time points over 24 h on two separate days. Volumes, creatinine and specific gravity were determined. All samples were analysed with a commercial ELISA for A1M. Results. We found a clear diurnal variation in A1M excretion rate and a gender effect (higher in males). The excretion rate was higher in the daytime, with high urinary flow, compared to overnight values. A1M excretion in spot urine samples was highly correlated with the 24 h excretion at all times except 22:00 in male subjects. Urinary A1M adjusted for creatinine concentration correlated well with the 24 h excretion. Variability within individuals was only 20% of the total variability in 24 h A1M excretion, but 43% in first morning urine. Expressed as CV, the intra-individual variability (between days) was 29% in 24 h excretion. Conclusion. We conclude that diurnal variation and gender should be taken into account when comparing groups. Moreover, in spot samples (e.g. first morning samples) adjustment of A1M for creatinine or specific gravity is a reliable alternative to 24 h urine.
引用
收藏
页码:1252 / 1256
页数:5
相关论文
共 18 条
[1]
Processing of the lipocalin α1-microglobulin by hemoglobin induces heme-binding and heme-degradation properties [J].
Allhorn, M ;
Berggård, T ;
Nordberg, J ;
Olsson, ML ;
Åkerström, B .
BLOOD, 2002, 99 (06) :1894-1901
[2]
Urine excretion of protein HC in proteinuric glomerular diseases correlates to urine IgG but not to albuminuria [J].
Bakoush, O ;
Grubb, A ;
Rippe, B ;
Tencer, J .
KIDNEY INTERNATIONAL, 2001, 60 (05) :1904-1909
[3]
Carrieri M, 2001, INT ARCH OCC ENV HEA, V74, P63
[4]
URINARY AND PLASMA ALPHA-1-GLYCOPROTEIN OF LOW-MOLECULAR WEIGHT - ISOLATION AND SOME PROPERTIES [J].
EKSTROM, B ;
PETERSON, PA ;
BERGGARD, I .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1975, 65 (04) :1427-1433
[5]
Age-related reference limits for urine levels of albumin, orosomucoid, immunoglobulin G and protein HC in children [J].
Hjorth, L ;
Helin, I ;
Grubb, A .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2000, 60 (01) :65-73
[6]
Diagnostic value of urinary alanine aminopeptidase and N-acetyl-β-D-glucosaminidase in comparison to α1-microglobulin as a marker in evaluating tubular dysfunction in glomerulonephritis patients [J].
Holdt-Lehmann, B ;
Lehmann, A ;
Korten, G ;
Nagel, HR ;
Nizze, H ;
Schuff-Werner, P .
CLINICA CHIMICA ACTA, 2000, 297 (1-2) :93-102
[7]
Hornung R.W., 1990, Appl. Occupat. Environ. Hygiene, V5, P46, DOI DOI 10.1080/1047322X.1990.10389587
[8]
Low level cadmium exposure, renal and bone effects -: the OSCAR study [J].
Järup, L ;
Alfvén, T .
BIOMETALS, 2004, 17 (05) :505-509
[9]
JUNG K, 1993, CLIN CHEM, V39, P757
[10]
Reference intervals for the markers of proteinuria with a standardised bed-rest collection of urine [J].
Kouri, T ;
Harmoinen, A ;
Laurila, K ;
Ala-Houhala, I ;
Koivula, T ;
Pasternack, A .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2001, 39 (05) :418-425