Assessment of tumour response with 18F-fluorodeoxyglucose positron emission tomography using three-dimensional measures compared to SUVmax -: a phantom study

被引:29
作者
Boucek, J. A. [1 ,2 ]
Francis, R. J. [2 ]
Jones, C. G. [1 ]
Khan, N. [3 ]
Turlach, B. A. [3 ]
Green, A. J. [4 ]
机构
[1] Sir Charles Gairdner Hosp, WA PET Serv, Nedlands, WA 6009, Australia
[2] Sir Charles Gairdner Hosp, Dept Nucl Med, Nedlands, WA 6009, Australia
[3] Univ Western Australia, Sch Math & Stat, Nedlands, WA 6009, Australia
[4] UCL, Royal Free Hosp, Canc Res UK Targeting & Imaging Grp, London, England
关键词
D O I
10.1088/0031-9155/53/16/001
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
SUVmax is currently the most common semi-quantitative method of response assessment on FDG PET. By defining the tumour volume of interest (VOI), a measure of total glycolytic volume (TGV) may be obtained. We aimed to comprehensively examine, in a phantom setting, the accuracy of TGV in reflecting actual lesion activity and to compare TGV with SUVmax for response assessment. The algorithms for VOI generation from which TGV was derived included fixed threshold techniques at 50% of maximum (MAX50), 70% of maximum (MAX70), an adaptive threshold of 50% of (maximum + background)/2 (BM50) and a semi- automated iterative region- growing algorithm, GRAB. Comparison with both actual lesion activity and response scenarioswas performed. SUVmax correlated poorly with actual lesion activity (r = 0.651) and change in lesion activity (r = 0.605). In a response matrix scenario SUVmax performed poorly when all scenarios were considered, but performed well when only clinically likely scenarios were included. The TGV derived using MAX50 and MAX70 algorithms performed poorly in evaluation of lesion change. The TGVderived from BM50 andGRABalgorithms however performed extremely well in correlation with actual lesion activity (r = 0.993 and r= 0.982, respectively), change in lesion activity (r= 0.972 and r= 0.963, respectively) and in the response scenario matrix. TGVGRAB demonstrated narrow confidence bands when modelled with actual lesion activity. Measures of TGV generated by iterative algorithms such as GRAB show potential for increased sensitivity of metabolic response monitoring compared to SUVmax, which may have important implications for improved patient care.
引用
收藏
页码:4213 / 4230
页数:18
相关论文
共 21 条
[1]
Akhurst, 2000, Clin Positron Imaging, V3, P57, DOI 10.1016/S1095-0397(00)00041-8
[2]
Response prediction by FDG-PET after neoadjuvant radiochemotherapy and combined regional hyperthermia of rectal cancer:: correlation with endorectal ultrasound and histopathology [J].
Amthauer, H ;
Denecke, T ;
Rau, B ;
Hildebrandt, B ;
Hünerbein, M ;
Ruf, J ;
Schneider, U ;
Gutberlet, M ;
Schlag, PM ;
Felix, R ;
Wust, P .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 (06) :811-819
[3]
Boellaard R, 2004, J NUCL MED, V45, P1519
[4]
BOUCEK J, 2005, J NUCL MED S, V46, P464
[5]
Erdi YE, 1997, CANCER, V80, P2505, DOI 10.1002/(SICI)1097-0142(19971215)80:12+<2505::AID-CNCR24>3.0.CO
[6]
2-F
[7]
FRANCIS RJ, 2005, J NUCL MED, V46, P102
[8]
GREEN AJ, 2001, EUR J NUCL MED S, V28, pS132
[9]
Hoekstra CJ, 2002, J NUCL MED, V43, P1304
[10]
Monitoring response to therapy in cancer using [18F]-2-fluouo-2-deoxy-D-glucose and positron emission tomography:: an overview of different analytical methods [J].
Hoekstra, CJ ;
Paglianiti, I ;
Hoekstra, OS ;
Smit, EF ;
Postmus, PE ;
Teule, GJJ ;
Lammertsma, AA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (06) :731-743