The sensitivity and specificity of tests for carpal tunnel syndrome vary with the comparison subjects

被引:44
作者
Gerr, F [1 ]
Letz, R [1 ]
机构
[1] Emory Univ, Rollins Sch Publ Hlth, Dept Environm & Occupat Med, Atlanta, GA 30322 USA
关键词
D O I
10.1016/S0266-7681(98)80163-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The performance of a variety of common office-based clinical tests for detection of carpal tunnel syndrome (CTS) was assessed in 119 subjects with and without electrophysiological evidence of LTS, Symptoms compatible with CTS and electrophysiological tests positive for median mononeuropathy at the wrist were observed in 57 hands, symptoms compatible with CTS and normal electrophysiological test results were observed in 58 hands, and no symptoms compatible with CTS and normal electrophysiological test results were observed in 123 hands. For all the diagnostic tests studied, the proportion of subjects who had a false positive clinical test result was much higher in the electrophysiologically normal subjects who had CTS compatible hand symptoms than in the electrophysiologically normal subjects who were asymptomatic. These results suggest that many studies that have evaluated diagnostic tests for CTS have produced falsely optimistic estimates of the test's performance because of their use of asymptomatic comparison subjects.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 13 条
[1]  
DAWSON DM, 1990, INTRAPMENT NEUROPATH, P25
[2]   EFFICACY OF PROVOCATIVE TESTS FOR DIAGNOSIS OF CARPAL-TUNNEL SYNDROME [J].
DEKROM, MCTFM ;
KNIPSCHILD, PG ;
KESTER, ADM ;
SPAANS, F .
LANCET, 1990, 335 (8686) :393-395
[3]  
GOLDING DN, 1986, BRIT J RHEUMATOL, V25, P388
[4]   CARPAL-TUNNEL DECOMPRESSION IN SPITE OF NORMAL ELECTROMYOGRAPHY [J].
GRUNDBERG, AB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1983, 8 (03) :348-349
[5]   THE CARPAL-TUNNEL SYNDROME - DIAGNOSTIC UTILITY OF THE HISTORY AND PHYSICAL-EXAMINATION FINDINGS [J].
KATZ, JN ;
LARSON, MG ;
SABRA, A ;
KRARUP, C ;
STIRRAT, CR ;
SETHI, R ;
EATON, HM ;
FOSSEL, AH ;
LIANG, MH .
ANNALS OF INTERNAL MEDICINE, 1990, 112 (05) :321-327
[6]  
Kimura J, 1989, ELECTRODIAGNOSIS DIS, P104
[7]   SPECTRUM BIAS IN THE EVALUATION OF DIAGNOSTIC-TESTS - LESSONS FROM THE RAPID DIPSTICK TEST FOR URINARY-TRACT INFECTION [J].
LACHS, MS ;
NACHAMKIN, I ;
EDELSTEIN, PH ;
GOLDMAN, J ;
FEINSTEIN, AR ;
SCHWARTZ, JS .
ANNALS OF INTERNAL MEDICINE, 1992, 117 (02) :135-140
[8]   TINEL SIGN AND THE CARPAL-TUNNEL SYNDROME [J].
MOSSMAN, SS ;
BLAU, JN .
BRITISH MEDICAL JOURNAL, 1987, 294 (6573) :680-680
[10]   PROBLEMS OF SPECTRUM AND BIAS IN EVALUATING EFFICACY OF DIAGNOSTIC TESTS [J].
RANSOHOFF, DF ;
FEINSTEIN, AR .
NEW ENGLAND JOURNAL OF MEDICINE, 1978, 299 (17) :926-930