Design and techno-economical optimization for hybrid PV/wind system under various meteorological conditions

被引:312
作者
Diaf, S. [1 ]
Notton, G. [1 ]
Belhamel, M. [2 ]
Haddadi, M. [3 ]
Louche, A. [1 ]
机构
[1] Univ Corse, CNRS, UMR 6134, Ctr Sci Vignola, F-20000 Ajaccio, France
[2] Ctr Dev Energies Renouvelables, Algiers 16340, Algeria
[3] Ecole Polytechn El Harrach, Algiers, Algeria
关键词
hybrid system; optimum system sizing; energy balance; cost analysis;
D O I
10.1016/j.apenergy.2008.02.012
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The optimal design of the renewable energy system can significantly improve the economical and technical performance of power supply. In this paper, the technical-economic optimization study of a stand-alone hybrid PV/wind system (HPWS) in Corsica Island is presented. Therefore, the primary objective of this study is to estimate the appropriate dimensions of a stand-alone HPWS that guarantee the energy autonomy of a typical remote consumer with the lowest levelised cost of energy (LCE). A secondary aim is to compare the performance and the optimal sizing of two system configurations. Finally, to study the impact of the renewable energy potential quality on the system size, the optimum dimensions of system are defined for five sites in Corsica Island. In this context, a complete sizing model is developed, able to predict the optimum system configuration on the basis of LCE. Accordingly, an integrated energy balance analysis is carried out for the whole time period investigated. The simulation results indicate that the hybrid system is the best option for all the sites considered in this study, yielding lower LCE. Thus, it provides higher system performance than PV or wind systems alone. The choice of the system configuration type affects the state of charge variation profile, especially at low wind potential sites, while the system size and the LCE are significantly influenced. It is shown that the LCE depends largely on the renewable energy potential quality. At high wind potential site, more than 40% of the total production energy is provided by the wind generator, while at low wind potential sites, less than 20% of total production energy is generated by the wind generator. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:968 / 987
页数:20
相关论文
共 19 条
[1]  
[Anonymous], INTRO SOLAR RAD
[2]  
[Anonymous], MAINTENANCE FREE BAT
[3]  
ATHANASIA AL, 2000, SOLAR ENERGY MAT SOL, V62, P411
[4]  
Bin A, 2003, Renew. Energy, V28, P1491
[5]  
BOGDAN SB, 1996, IEEE T ENERGY CONVER, V11, P367
[6]   Diffuse solar irradiation model evaluation in the North Mediterranean belt area [J].
De Miguel, A ;
Bilbao, J ;
Aguiar, R ;
Kambezidis, H ;
Negro, E .
SOLAR ENERGY, 2001, 70 (02) :143-153
[7]   A methodology or optimal sizing of autonomous hybrid PV/wind system [J].
Diaf, S. ;
Diaf, D. ;
Belhamel, M. ;
Haddadi, M. ;
Louche, A. .
ENERGY POLICY, 2007, 35 (11) :5708-5718
[8]   AN OPTIMAL SIZING METHOD FOR STAND-ALONE PHOTOVOLTAIC POWER-SYSTEMS [J].
GROUMPOS, PP ;
PAPAGEORGIOU, G .
SOLAR ENERGY, 1987, 38 (05) :341-351
[9]   Optimization procedure of a hybrid photovoltaic wind energy system [J].
Habib, MA ;
Said, SAM ;
El-Hadidy, MA ;
Al-Zaharna, I .
ENERGY, 1999, 24 (11) :919-929
[10]   Wind potential assessment of Quebec Province [J].
Ilinca, A ;
McCarthy, E ;
Chaumel, JL ;
Rétiveau, JL .
RENEWABLE ENERGY, 2003, 28 (12) :1881-1897