Breast Cancer: Missed Interval and Screening-detected Cancer at Full-Field Digital Mammography and Screen-Film Mammography-Results from a Retrospective Review

被引:80
作者
Hoff, Solveig R. [1 ,3 ]
Abrahamsen, Anne-Line [4 ]
Samset, Jon Helge [1 ]
Vigeland, Einar [4 ]
Klepp, Olbjorn [2 ,3 ]
Hofvind, Solveig [5 ]
机构
[1] Helse More & Romsdal HF, Aalesund Hosp, Dept Radiol, N-6026 Alesund, Norway
[2] Helse More & Romsdal HF, Aalesund Hosp, Dept Oncol, N-6026 Alesund, Norway
[3] Natl Univ Sci & Technol, Dept Canc Res & Mol Med, Trondheim, Norway
[4] Vestfold Hosp, Dept Radiol, Tonsberg, Norway
[5] Canc Registry Norway, Dept Res, Oslo, Norway
关键词
COMPUTER-AIDED DETECTION; PROGRAM; NORWAY;
D O I
10.1148/radiol.12112074
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the percentages and mammographic features of cancers missed at full-field digital mammography (FFDM) and screen-film mammography (SFM) in women who participated in the Norwegian Breast Cancer Screening Program in 2002-2008. Materials and Methods: Social Science Data Services approval was obtained; the requirement for informed consent was waived. Cases were all the interval and screening-detected cancers from 35 127 FFDM and 52 444 SFM examinations in two Norwegian counties. Prior and diagnostic FFDM examinations of 49 interval and 86 screening-detected breast cancers were reviewed by four breast radiologists and compared with a review of SFM examinations of 81 interval and 123 screening-detected cancers. Cancers were classified as missed or true, mammographic features were described, percentages were compared by using the chi(2) or Fisher exact test, and 95% confidence intervals (CIs) were calculated. Results: The percentages of interval and screening-detected cancers missed at FFDM and SFM did not differ significantly. (interval cancers missed: 33% [16 of 49] at FFDM vs 30% [24 of 81] at SFM [P = .868]; screening-detected cancers missed: 20% [17 of 86] at FFDM vs 21% [26 of 123] at SFM [P = .946]). Asymmetry was present in 27% (95% CI: 13.3%, 45.5%) of prior mammograms of cancers missed at FFDM and 10% (95% CI: 3.3%, 21.8%) of those missed at SFM (P = .070). Calcifications were observed in 18% (95% CI: 7.0%, 35.5%) of the cancers missed at FFDM and 34% (95% CI: 21.2%, 48.8%) of those missed at SFM (P = .185). Average mammographic tumor size of missed cancers manifesting as masses was 10.4 mm at FFDM and 13.6 mm at SFM (P = .036). Conclusion: The use of FFDM has not reduced the challenge of missed cancers. Cancers missed at FFDM tend to have different mammographic features than those missed at SFM. (c) RSNA, 2012
引用
收藏
页码:378 / 386
页数:9
相关论文
共 24 条
[1]   "CADEAT": considerations on the use of CAD (computer-aided diagnosis) in mammography [J].
Chersevani, R. ;
Ciatto, S. ;
Del Favero, C. ;
Frigerio, A. ;
Giordano, L. ;
Giuseppetti, G. ;
Naldoni, C. ;
Panizza, P. ;
Petrella, M. ;
Saguatti, G. .
RADIOLOGIA MEDICA, 2010, 115 (04) :563-570
[2]   Interval breast cancers in screening: The effect of mammography review method on classification [J].
Ciatto, Stefano ;
Catarzi, Sandra ;
Lamberini, Maria Perla ;
Risso, Gabriella ;
Saguatti, Gianni ;
Abbattista, Teresa ;
Martinelli, Francesca ;
Houssami, Nehmat .
BREAST, 2007, 16 (06) :646-652
[3]   Impact of computer-aided detection in a regional screening mammography program [J].
Cupples, TE ;
Cunningham, JE ;
Reynolds, JC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (04) :944-950
[4]  
D'Orsi C.J., 2003, Breast imaging reporting and data system (BI-RADS) breast imaging atlas
[5]   Improved cancer detection using computer-aided detection with diagnostic and screening mammography: Prospective study of 104 cancers [J].
Dean, Judy C. ;
Ilvento, Christina C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (01) :20-28
[6]   Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography [J].
Fischer, U ;
Baum, F ;
Obenauer, S ;
Luftner-Nagel, S ;
von Heyden, D ;
Vosshenrich, R ;
Grabbe, E .
EUROPEAN RADIOLOGY, 2002, 12 (11) :2679-2683
[7]   Screening mammography with computer-aided detection: Prospective study of 12,860 patients in a community breast center [J].
Freer, TW ;
Ulissey, MJ .
RADIOLOGY, 2001, 220 (03) :781-786
[8]   Comparison of Digital Mammography and Screen-Film Mammography in Breast Cancer Screening: A Review in the Irish Breast Screening Program [J].
Hambly, Niamh M. ;
McNicholas, Michelle M. ;
Phelan, Niall ;
Hargaden, Gormlaith C. ;
O'Doherty, Ann ;
Flanagan, Fidelma L. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (04) :1010-1018
[9]   Missed and True Interval and Screen-detected Breast Cancers in a Population Based Screening Program [J].
Hoff, Solveig Roth ;
Samset, Jon Helge ;
Abrahamsen, Anne-Line ;
Vigeland, Einar ;
Klepp, Olbjorn ;
Hofvind, Solveig .
ACADEMIC RADIOLOGY, 2011, 18 (04) :454-460
[10]   Influence of review design on percentages of missed interval breast cancers: Retrospective study of interval cancers in a population-based screening program [J].
Hofvind, S ;
Skaane, P ;
Vitak, B ;
Wang, H ;
Thoresen, S ;
Eriksen, L ;
Bjorndal, H ;
Braaten, A ;
Bjurstam, N .
RADIOLOGY, 2005, 237 (02) :437-443