Estimation of intra-abdominal pressure by bladder pressure measurement: Validity and methodology

被引:137
作者
Fusco, MA
Martin, RS
Chang, MC
机构
[1] Wake Forest Univ, Bowman Gray Sch Med, Dept Gen Surg, Winston Salem, NC 27157 USA
[2] Melbourne Internal Med Associates, Melbourne, FL USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2001年 / 50卷 / 02期
关键词
bladder pressure; intra-abdominal pressure; abdominal compartment syndrome; intra-abdominal hypertension; abdominal decompression; urinary catheterization; manometry; bladder volume; monitoring techniques;
D O I
10.1097/00005373-200102000-00016
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Increased intra-abdominal pressure (IAP) is an adverse complication seen in critically ill, injured, and postoperative patients. IAP is estimated via the measurement of bladder pressure. Few studies have been performed to establish the actual relationship between IAP and bladder pressure. The purpose of this study was to confirm the association between intravesicular pressure and IAP and to determine the bladder volume that best approximates IAP, Methods: Thirty-seven patients undergoing laparoscopy had intravesicular pressures measured with bladder volumes of 0, 50, 100, 150, and 200 mi, at directly measured intra-abdominal pressures of 0, 5, 10, 15, 20, and 25 mm Hg, Correlation coefficients and differences were then determined. Results: Across the IAP range of 0 to 25 mm tig using all of the tested bladder volumes, the difference between IAP and intravesicular pressures (bias) was -3.8 +/- 0.29 mm Hg (95% confidence interval) and measurements were well correlated (R-2 = 0.68), Assessing all IAPs tested, a bladder volume of 0 mt demonstrated the lowest bias (-0.79 +/- 0.73 mm Hg). When considering only elevated IAPs (25 mm tig), a bladder volume of 50 mt revealed the lowest bias (-1.5 +/- 1.36 mm Hg), A bladder volume of 50 mt in patients with elevated IAP resulted in an intravesicular pressure 1 to 3 mm Hg higher than IAP (95% confidence interval). Conclusion: Intravesicular pressure closely approximates IAP, Instillation of 50 mt of liquid into the bladder improves the accuracy of the intravesicular pressure in measuring elevated IAPs.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 53 条
[1]   CARDIOVASCULAR-RESPONSES TO ELEVATION OF INTRA-ABDOMINAL HYDROSTATIC-PRESSURE [J].
BARNES, GE ;
LAINE, GA ;
GIAM, PY ;
SMITH, EE ;
GRANGER, HJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1985, 248 (02) :R208-R213
[2]  
BENDAHAN J, 1995, J TRAUMA, V180, P745
[3]   Effects of increased intra-abdominal pressure upon intracranial and cerebral perfusion pressure before and after volume expansion [J].
Bloomfield, GL ;
Ridings, PC ;
Blocher, CR ;
Marmarou, A ;
Sugerman, HJ .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 40 (06) :936-941
[4]   A proposed relationship between increased intraabdominal, intrathoracic, and intracranial pressure [J].
Bloomfield, GL ;
Ridings, PC ;
Blocher, CR ;
Marmarou, A ;
Sugerman, HJ .
CRITICAL CARE MEDICINE, 1997, 25 (03) :496-503
[5]   THE EFFECT OF INCREASED INTRA ABDOMINAL PRESSURE ON RENAL FUNCTION IN MAN [J].
BRADLEY, SE ;
BRADLEY, GP .
JOURNAL OF CLINICAL INVESTIGATION, 1947, 26 (05) :1010-1022
[6]   The abdominal compartment syndrome [J].
Burch, JM ;
Moore, EE ;
Moore, FA ;
Franciose, R .
SURGICAL CLINICS OF NORTH AMERICA, 1996, 76 (04) :833-+
[7]  
Cade R, 1987, Am J Med, V82, P427, DOI 10.1016/0002-9343(87)90442-6
[8]   CHANGES IN VISCERAL BLOOD-FLOW WITH ELEVATED INTRAABDOMINAL PRESSURE [J].
CALDWELL, CB ;
RICOTTA, JJ .
JOURNAL OF SURGICAL RESEARCH, 1987, 43 (01) :14-20
[9]   Effects of abdominal decompression on cardiopulmonary function and visceral perfusion in patients with intra-abdominal hypertension [J].
Chang, MC ;
Miller, PR ;
D'Agostino, R ;
Meredith, JW .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1998, 44 (03) :440-445
[10]   Intraabdominal pressure: A revised method for measurement (vol 186, pg 368, 1998) [J].
Cheatham, ML ;
Safcsak, K .
JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1998, 186 (05) :594-595