Development of a sensor prepared by entrapment of MIP particles in electrosynthesised polymer films for electrochemical detection of ephedrine

被引:113
作者
Mazzotta, E. [1 ]
Picca, R. A. [1 ]
Malitesta, C. [1 ]
Piletsky, S. A. [2 ]
Piletska, E. V. [2 ]
机构
[1] Univ Salento, Dipartimento Sci Mat, Lab Chim Analit, I-73100 Lecce, Italy
[2] Cranfield Univ, Silsoe MK45 4DT, Beds, England
关键词
molecular imprinting; electrochemical sensor; polypyrrole; ephedrine;
D O I
10.1016/j.bios.2007.09.020
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A voltammetric sensor for (-)-ephedrine has been prepared by a novel approach based on immobilisation of an imprinted polymer for ephedrine (MIPE) in an electrosynthesised polypyrrole (PPY) film. Composite films were grown potentiostatically at 1.0 V vs. Pt (QRE) on a glassy carbon electrode using an unconventional "upside-down" (UD) geometry for the three-electrode cell. As a consequence, a high MIP loading was obtained, as revealed by SEM. The sensor response was evaluated, after overoxidation of PPY matrix, by cyclic voltammetry after pre-concentration in a buffered solution of analyte in 0.5-3 mM concentration range. An ephedrine peak at approximate to 0.9 V increasing with concentration and saturating at high concentrations was evident. PPY-modified electrode showed a response, which was distinctly lower than the MIP response for the same concentration of the template. The effect of potential interferences including compounds usually found in human fluids (ascorbic acid, uric acid, urea, glucose, sorbitol, glycine, dopamine) was examined. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1152 / 1156
页数:5
相关论文
共 32 条
  • [1] Electrochemical sensing with electrodes modified with molecularly imprinted polymer films
    Blanco-López, MC
    Gutiérrez-Fernández, S
    Lobo-Castañón, MJ
    Miranda-Ordieres, AJ
    Tuñón-Blanco, P
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (08) : 1922 - 1928
  • [2] INTERFERENCE-FREE GLUCOSE SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN OVEROXIDIZED NONCONDUCTING POLYPYRROLE FILM
    CENTONZE, D
    GUERRIERI, A
    MALITESTA, C
    PALMISANO, F
    ZAMBONIN, PG
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (09): : 729 - 733
  • [3] DETERMINATION OF EPHEDRINE IN HUMAN URINE USING A GLASSY-CARBON ELECTRODE
    CHICHARRO, M
    ZAPARDIEL, A
    BERMEJO, E
    PEREZ, JA
    HERNANDEZ, L
    [J]. ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) : 361 - 368
  • [4] CHICHARRO M, 1995, ANALUSIS, V23, P131
  • [5] EPHEDRINE DETERMINATION IN HUMAN URINE USING A CARBON-PASTE ELECTRODE MODIFIED WITH C-18 BONDED SILICA-GEL
    CHICHARRO, M
    ZAPARDIEL, A
    BERMEJO, E
    PEREZ, JA
    HERNANDEZ, L
    [J]. ANALYTICAL LETTERS, 1994, 27 (10) : 1809 - 1831
  • [6] Flow injection-pulse amperometric detection of ephedrine at a cobalt phthalocyanine modified carbon paste electrode
    Cookeas, EG
    Efstathiou, CE
    [J]. ANALYST, 2000, 125 (06) : 1147 - 1150
  • [7] Molecular imprinting in chemical sensing - Detection of aromatic and halogenated hydrocarbons as well as polar solvent vapors
    Dickert, FL
    Forth, P
    Lieberzeit, P
    Tortschanoff, M
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (7-8): : 759 - 762
  • [8] Biosensor for the determination of sorbitol based on molecularly imprinted electro synthesized polymers
    Feng, L
    Liu, Y
    Tan, Y
    Hu, J
    [J]. BIOSENSORS & BIOELECTRONICS, 2004, 19 (11) : 1513 - 1519
  • [9] Molecularly imprinted polymers and their use in biomimetic sensors
    Haupt, K
    Mosbach, K
    [J]. CHEMICAL REVIEWS, 2000, 100 (07) : 2495 - 2504
  • [10] Indirect determination of ephedrine in urine by differential pulse polarography
    Hernandez, L
    Zapardiel, A
    Bermejo, E
    Perez, JA
    Chicharro, M
    Garijo, MJ
    [J]. ELECTROANALYSIS, 1997, 9 (15) : 1214 - 1218