Microcomputed tomography colonography for polyp detection in an in vivo mouse tumor model

被引:27
作者
Pickhardt, PJ
Halberg, RB
Taylor, AJ
Durkee, BY
Fine, J
Lee, FT
Weichert, JP
机构
[1] Univ Wisconsin, Sch Med, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin, Sch Med, Dept Biostat, Madison, WI 53792 USA
[3] Univ Wisconsin, McArdle Lab Canc Res, Madison, WI 53706 USA
关键词
colonic neoplasm;
D O I
10.1073/pnas.0409915102
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 [理学]; 0710 [生物学]; 09 [农学];
摘要
This study was initiated to evaluate the efficacy of negative contrast-enhanced microcomputed tomography (microCT) colonography for the noninvasive detection of colonic tumors in living mice. After colonic preparation, 20 anesthetized congenic mice were scanned with high-resolution microCT. Images were displayed by using commercial visualization software and interpreted by two gastrointestinal radiologists, who were unaware of tumor prevalence and findings at gross pathology. Two-dimensional multiplanar images were assessed by using a five-point scale to distinguish colonic tumors (polyps) from fecal pellets (5 = definitely a tumor, 4 = probably a tumor, 3 = indeterminate, 2 = probably not a tumor, 1 = definitely not a tumor). Gross pathologic evaluation of excised mouse colons served as the reference standard. Data analysis included dichotomizing results, with 1-2 indicating no tumor and 3-5 indicating tumor and also receiver operator characteristic curve analysis with area under the curve for threshold-independent assessment. A total of 41 colonic polyps in 18 of the 20 mice were identified at gross examination on necropsy, of which 30 measured 2-5 mm and 11 measured <2 mm in size. The pooled per-polyp sensitivity for lesions >2 mm was 93.3% (56/60). The pooled per-mouse sensitivity for polyps >2 mm was 97.1% (33/34). Pooled specificity for distinguishing fecal pellets from tumor was 98.5% (65/66). The combined area under the curve from receiver operator characteristic curve analysis was 0.810 +/- 0.038 (95% confidence interval, 0.730-0.890). These findings indicate that accurate noninvasive longitudinal monitoring of colon tumor progression or response to various therapies is now technically feasible in live mice by using this microCT colonography method.
引用
收藏
页码:3419 / 3422
页数:4
相关论文
共 24 条
[1]
The use of microcomputed tomography to study microvasculature in small rodents [J].
Bentley, MD ;
Ortiz, MC ;
Ritman, EL ;
Romero, JC .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2002, 282 (05) :R1267-R1279
[2]
Bond JH, 2003, ENDOSCOPY, V35, pS35
[3]
Boone John M, 2004, Mol Imaging, V3, P149, DOI 10.1162/1535350042380326
[4]
Cavanaugh Dawn, 2004, Mol Imaging, V3, P55, DOI 10.1162/153535004773861723
[5]
Bioluminescent indicators in living mammals [J].
Contag, PR ;
Olomu, IN ;
Stevenson, DK ;
Contag, CH .
NATURE MEDICINE, 1998, 4 (02) :245-247
[6]
Three-dimensional microcomputed tomography of renal vasculature in rats [J].
Garcia-Sanz, A ;
Rodriguez-Barbero, A ;
Bentley, MD ;
Ritman, EL ;
Romero, JC .
HYPERTENSION, 1998, 31 (01) :440-444
[7]
Advanced imaging of the macrostructure and microstructure of bone [J].
Genant, HK ;
Gordon, C ;
Jiang, YB ;
Link, TM ;
Hans, D ;
Majumdar, S ;
Lang, TF .
HORMONE RESEARCH, 2000, 54 :24-30
[8]
MAGNETIC-RESONANCE MICROSCOPY OF THE RAT THORAX AND ABDOMEN [J].
HEDLUND, LW ;
JOHNSON, GA ;
MILLS, GI .
INVESTIGATIVE RADIOLOGY, 1986, 21 (11) :843-846
[9]
Micro-CT in small animal and specimen imaging [J].
Holdsworth, David W. ;
Thornton, Michael M. .
TRENDS IN BIOTECHNOLOGY, 2002, 20 (08) :S34-S39
[10]
Micro-computed tomography evaluation of trabecular bone structure on loaded mice tail vertebrae [J].
Issever, AS ;
Walsh, A ;
Lu, Y ;
Burghardt, A ;
Lotz, JC ;
Majumdar, S .
SPINE, 2003, 28 (02) :123-128