The aim of this study was to investigate the adsorption and desorption kinetics of antibiotics to microporous bioceramics fabricated by a novel low temperature 3D powder direct printing process. The adsorption of vancomycin, ofloxacin and tetracycline onto hydroxyapatite, brushite and monetite showed a linear correlation with the drug concentration in the immersion solution, whereas a non-linear relationship was found between the immersion time and the amount of adsorbed drug. Differences in the total amount of adsorbed drugs were correlated to the specific surface areas of the matrices, which varied between 2.4-13.1 m(2)/g. Normalised drug loadings were found to be in the range of 1.5-1.8 mg/m(2) for vancomycin and ofloxacin, whereas higher loads of up to 5-7 mg/m(2) were obtained for tetracycline. Vancomycin and ofloxacin were rapidly released into PBS buffer within 1-2 days, while tetracycline showed a much slower release rate of approximately 25% after 5 days of immersion. Additional polymer impregnation of the drug loaded matrix with PLA/PGA polymer solutions enabled the release kinetics to be delayed such that sustained release was achieved in polymer ceramic biocomposites. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:173 / 180
页数:8
相关论文
共 54 条
[1]   Release profile of antimicrobial agents from α-tricalcium phosphate cement [J].
Akashi, A ;
Matsuya, Y ;
Unemori, M ;
Akamine, A .
BIOMATERIALS, 2001, 22 (20) :2713-2717
[2]   Tetracycline-HCl-loaded poly(DL-lactide-co-glycolide) microspheres prepared by a spray drying technique:: influence of γ-irradiation on radical formation and polymer degradation [J].
Bittner, B ;
Mäder, K ;
Kroll, C ;
Borchert, HH ;
Kissel, T .
JOURNAL OF CONTROLLED RELEASE, 1999, 59 (01) :23-32
[3]   Gentamicin-loaded hydraulic calcium phosphate bone cement as antibiotic delivery system [J].
Bohner, M ;
Lemaitre, J ;
VanLanduyt, P ;
Zambelli, PY ;
Merkle, HP ;
Gander, B .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1997, 86 (05) :565-572
[4]  
Bohner M, 2000, Injury, V31 Suppl 4, P37
[5]  
Bohner M, 2000, J PHARM SCI, V89, P1262, DOI 10.1002/1520-6017(200010)89:10<1262::AID-JPS4>3.3.CO
[6]  
2-Z
[7]   TISSUE COMPATIBILITY OF GENTAMICIN PMMA BEADS AND CHAINS [J].
BONK, U ;
FRIEDEN, H .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1979, 93 (03) :241-242
[8]   Use of commercial porous ceramic particles for sustained drug delivery [J].
Byrne, RS ;
Deasy, PB .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2002, 246 (1-2) :61-73
[9]  
Cabanillas PF, 2000, INT J PHARM, V209, P15
[10]   Ciprofloxacin implants for bone infection.: In vitro-in vivo characterization [J].
Castro, C ;
Sánchez, E ;
Delgado, A ;
Soriana, I ;
Núñez, P ;
Baro, M ;
Perera, A ;
Évora, C .
JOURNAL OF CONTROLLED RELEASE, 2003, 93 (03) :341-354