Radiation protection for the sentinel node procedure in breast cancer

被引:24
作者
de Kanter, AY
Arends, PPAM
Eggermont, AMM
Wiggers, T
机构
[1] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, Dept Surg Oncol, NL-3075 EA Rotterdam, Netherlands
[2] Univ Rotterdam Hosp, Dr Daniel Den Hoed Canc Ctr, Div Radiat Protect, NL-3075 EA Rotterdam, Netherlands
来源
EUROPEAN JOURNAL OF SURGICAL ONCOLOGY | 2003年 / 29卷 / 04期
关键词
sentinel node; radiation protection; surgeon; pathologist; breast cancer; safety;
D O I
10.1053/ejso.2002.1424
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Aims: The purpose of our study was to determine the radiation dose for those who are involved in the sentinel node procedure in breast cancer patients and testing of a theoretical model. Methods: We studied 12 consecutive breast cancer patients undergoing breast surgery, and a sentinel node dissection including an axillary lymph node dissection (ALND). We performed measurements on the surgeon, the assistant, the theatre nurse, the pathologist and his assistant. Results: The measurements on the theatre nurse and both pathologist as his assistant are beneath the detection limit of 10 muSv. The highest measured doses are the hands of the surgeon and his assistant (17-61 muSv), however the dose limits for hands are higher than for other parts of the body. Taking the dose limits into account the abdominal wall of the surgeon relatively receives the highest dose, with an average of 8.2 muSv per procedure. Conclusion: Radiation dose levels are less than the established dose limits for (nonexposed) workers if the number of procedures is restricted to about 100/person/year. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:396 / 399
页数:4
相关论文
共 11 条
[1]
Sentinel node staging of early breast cancer using lymphoscintigraphy and the intraoperative gamma detecting probe [J].
Alazraki, NP ;
Styblo, T ;
Grant, SF ;
Cohen, C ;
Larsen, T ;
Waldrop, S ;
Aarsvold, JN .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2001, 39 (05) :947-+
[2]
Brenner W, 2000, NUKLEARMED-NUCL MED, V39, P142
[3]
Radiation protection in radioguided surgery of breast cancer [J].
Cremonesi, M ;
Ferrari, M ;
Sacco, E ;
Rossi, A ;
De Cicco, C ;
Leonardi, L ;
Chinol, M ;
Luini, A ;
Galimberti, V ;
Tosi, G ;
Veronesi, U ;
Paganelli, G .
NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (10) :919-924
[4]
*DUTCH SOC RAD PRO, 1995, NVS PUBL, V25
[5]
LYMPHATIC MAPPING AND SENTINEL LYMPHADENECTOMY FOR BREAST-CANCER [J].
GIULIANO, AE ;
KIRGAN, DM ;
GUENTHER, JM ;
MORTON, DL .
ANNALS OF SURGERY, 1994, 220 (03) :391-401
[6]
Guidelines for the safe use of radioactive materials during localization and resection of the sentinel lymph node [J].
Miner, TJ ;
Shriver, CD ;
Flicek, PR ;
Miner, FC ;
Jaques, DP ;
Maniscalco-Theberge, ME ;
Krag, DN .
ANNALS OF SURGICAL ONCOLOGY, 1999, 6 (01) :75-82
[7]
Validation of the accuracy of intraoperative lymphatic mapping and sentinel lymphadenectomy for early-stage melanoma - A multicenter trial [J].
Morton, DL ;
Thompson, JF ;
Essner, R ;
Elashoff, R ;
Stern, SL ;
Nieweg, OE ;
Roses, DF ;
Karakousis, CP ;
Mozzillo, N ;
Reintgen, D ;
Wang, HJ ;
Glass, EC ;
Cochran, AJ .
ANNALS OF SURGERY, 1999, 230 (04) :453-463
[8]
Radiation safety with breast sentinel node biopsy [J].
Stratmann, SL ;
McCarty, TM ;
Kuhn, JA .
AMERICAN JOURNAL OF SURGERY, 1999, 178 (06) :454-457
[9]
Sentinel-node biopsy to avoid axillary dissection in breast cancer with clinically negative lymph-nodes [J].
Veronesi, U ;
Paganelli, G ;
Galimberti, V ;
Viale, G ;
Zurrida, S ;
Bedoni, M ;
Costa, A ;
deCicco, C ;
Geraghty, JG ;
Luini, A ;
Sacchini, V ;
Veronesi, P .
LANCET, 1997, 349 (9069) :1864-1867
[10]
Waddington WA, 2000, EUR J NUCL MED, V27, P277