RELIABILITY AND VALIDITY OF A DEVICE TO MEASURE MUSCLE HARDNESS

被引:10
作者
Kato, Gohei [1 ]
Andrew, Paul D. [2 ]
Sato, Haruhiko [3 ]
机构
[1] Oxford Brookes Univ, Sch Social Sci & Law, Oxford OX3 0BP, England
[2] Ibaraki Prefectural Univ Hlth Sci, Dept Phys Therapy, Ami, Ibaraki 3000394, Japan
[3] Kitasato Univ, Phys Therapy Course, Fac Rehabil, Sch Allied Hlth Sci, Sagamihara, Kanagawa 228, Japan
关键词
Myotonometer; muscle tension; muscle hardness; surface electromyography; biceps brachii; brachioradialis;
D O I
10.1142/S0219519404000989
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Although clinicians judge muscle tenseness by palpation, methods to quantify this have not become established. We examined the reliability and validity of a commercially available myotonometer to assess the biceps brachii and brachioradialis. Torques ranging from 0-72% of maximum effort were isometrically resisted in five men and five women, all healthy and 21-23 years of age. Root-mean-square of surface electromyographic response was also measured. Intraclass correlations were 0.80 or higher within sessions but decreased to 0.57 between sessions except for myotonometry of the biceps brachii. Correlation with isometric load was 0.79 or higher for both myotonometry and electromyography, but these relations were consistently curvilinear. The myotonometer is more useful for fleshy muscles like the biceps brachii than for thin muscles like the brachioradialis. Because hardness has a curvilinear relation with tension in the muscle, hardness cannot be considered strictly equivalent to tension.
引用
收藏
页码:213 / 225
页数:13
相关论文
共 13 条
[1]   Measurement of muscle hardness: a methodological study [J].
Ashina, M ;
Bendtsen, L ;
Jensen, R ;
Sakai, F ;
Olesen, J .
CEPHALALGIA, 1998, 18 (02) :106-111
[2]   INTEGRATED ACTIONS AND FUNCTIONS OF THE CHIEF FLEXORS OF THE ELBOW - A DETAILED ELECTROMYOGRAPHIC ANALYSIS [J].
BASMAJIAN, JV ;
LATIF, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1957, 39 (05) :1106-1118
[3]   MUSCLE PALPATION WITH CONTROLLED FINGER PRESSURE - NEW EQUIPMENT FOR THE STUDY OF TENDER MYOFASCIAL TISSUES [J].
BENDTSEN, L ;
JENSEN, R ;
JENSEN, NK ;
OLESEN, J .
PAIN, 1994, 59 (02) :235-239
[4]   NONINVASIVE MEASUREMENT METHOD FOR HARDNESS IN MUSCULAR TISSUES [J].
HORIKAWA, M ;
EBIHARA, S ;
SAKAI, F ;
AKIYAMA, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1993, 31 (06) :623-627
[5]   Muscle contraction and relaxation described by tactile stiffness [J].
Inaba, H ;
Miyaji, K ;
Kaneko, Y ;
Ohtsuka, T ;
Takamoto, S ;
Omata, S .
ARTIFICIAL ORGANS, 2001, 25 (01) :42-46
[6]   RELATION OF HUMAN ELECTROMYOGRAM TO MUSCULAR TENSION [J].
INMAN, VT ;
RALSTON, HJ ;
SAUNDERS, JBDM ;
FEINSTEIN, B ;
WRIGHT, EW .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1952, 4 (02) :187-194
[7]  
Kato M., 1979, Japanese Journal of Medical Electronics and Biological Engineering, V17, P258
[8]  
Konno Y, 1952, TAIRYOKU KAGAKU, V1, P180
[9]   THE RELATION BETWEEN INTEGRATED ACTION POTENTIALS IN A HUMAN MUSCLE AND ITS ISOMETRIC TENSION [J].
LIPPOLD, OCJ .
JOURNAL OF PHYSIOLOGY-LONDON, 1952, 117 (04) :492-499
[10]  
Noyons A, 1911, Z BIOL-MUNICH, V56, P139