Adaptive control of external carbon flow rate in an activated sludge process

被引:27
作者
Lindberg, CF
Carlsson, B
机构
关键词
activated sludge process; adaptive control; external carbon; denitrification; nitrate; wastewater treatment;
D O I
10.1016/0273-1223(96)84212-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study an adaptive carbon flow rate controller is applied to a pre-denitrifying pilot-scale plant. The goal of the control strategy is to maintain a low nitrate concentration in the anoxic zone by controlling the external flow rate of the carbon source. Results from practical experiments show that the control strategy works well and the nitrate Concentration could be kept close to a desired set-point (reference value). The used nitrate sensor needed, however, frequent maintenance. During the experiment the carbon flow rate was automatically varied to keep the nitrate concentration at a constant low level. We conclude that a low effluent nitrate concentration without an excessive carbon flow rate is hard to achieve without an automatic control strategy. Copyright (C) 1996 IAWQ. Published by Elsevier Science Ltd.
引用
收藏
页码:173 / 180
页数:8
相关论文
共 16 条
[1]  
AHLEN A, 1988, INTRO ADAPTIVE CONTR
[2]  
Andersson B., 1995, METHANOL ETHANOL EXT
[3]   MODEL AND SENSOR BASED OPTIMIZATION OF NITROGEN REMOVAL AT KLAGSHAMN WASTE-WATER TREATMENT-PLANT [J].
ASPEGREN, H ;
ANDERSSON, B ;
NYBERG, U ;
JANSEN, JL .
WATER SCIENCE AND TECHNOLOGY, 1992, 26 (5-6) :1315-1323
[4]  
Astrom K. J., 1989, Adaptive Control, V2nd
[5]  
CARLSSON B, 1995, 9 FOR APPL BIOT 27 2, P2491
[6]   SELF-TUNING CONTROLLER [J].
CLARKE, DW ;
GAWTHROP, PJ .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1975, 122 (09) :929-934
[7]  
HASSELBLAD S, 1996, IWAQ 18 BIENN INT C
[8]  
HELSTROM BG, 1990, STYRSTRATEGIER AV TI
[9]  
LATOMAA J, 1994, THESIS UPPSALA U
[10]  
LINDBERG CF, 1995, 95071R UPT4EC UPPS U