Titanium alloys in total joint replacement - a materials science perspective

被引:3054
作者
Long, M [1 ]
Rack, HJ [1 ]
机构
[1] Clemson Univ, Sch Chem & Mat Engn, Clemson, SC 29634 USA
关键词
titanium; titanium alloys; total joint replacement; orthopaedics; fatigue; wear; biocompatibility;
D O I
10.1016/S0142-9612(97)00146-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Increased use of titanium alloys as biomaterials is occurring due to their lower modulus, superior biocompatibility and enhanced corrosion resistance when compared to more conventional stainless steels and cobalt-based alloys. These attractive properties were a driving force for the early introduction of alpha (cpTi) and alpha + beta (Ti-6A1-4V) alloys as well as for the more recent development of new Ti-alloy compositions and orthopaedic metastable beta titanium alloys. The later possess enhanced biocompatibility, reduced elastic modulus, and superior strain-controlled and notch fatigue resistance. However, the poor shear strength and wear resistance of titanium alloys have nevertheless limited their biomedical use. Although the wear resistance of beta-Ti alloys has shown some improvement when compared to alpha + beta alloys, the ultimate utility of orthopaedic titanium alloys as wear components will require a more complete fundamental understanding of the wear mechanisms involved. This review examines current information on the physical and mechanical characteristics of titanium alloys used in artifical joint replacement prostheses, with a special focus on those issues associated with the long-term prosthetic requirements, e.g., fatigue and wear. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1621 / 1639
页数:19
相关论文
共 145 条
  • [1] METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS
    AGINS, HJ
    ALCOCK, NW
    BANSAL, M
    SALVATI, EA
    WILSON, PD
    PELLICCI, PM
    BULLOUGH, PG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) : 347 - 356
  • [2] Ahmed T., 1995, 8 WORLD TIT C BIRM U
  • [3] *AM AC ORTH SURG, 1995, OTH RES SOC ANN M OR
  • [4] ARDILL J, 1995, THESIS QUEENS U BELF
  • [5] POLYETHYLENE WEAR IN MENISCAL KNEE REPLACEMENT - A ONE TO 9-YEAR RETRIEVAL ANALYSIS OF THE OXFORD KNEE
    ARGENSON, JN
    OCONNOR, JJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (02): : 228 - 232
  • [6] BANIA PJ, 1993, BETA TITANIUM ALLOYS IN THE 1990S, P3
  • [7] BERRY DJ, 1993, CLIN ORTHOP RELAT R, V293, P204
  • [8] FRETTING FATIGUE AND FRETTING WEAR
    BERTHIER, Y
    VINCENT, L
    GODET, M
    [J]. TRIBOLOGY INTERNATIONAL, 1989, 22 (04) : 235 - 242
  • [9] BERTHIER Y, 1992, EUR C BRAK LILL FRAN, P1
  • [10] SELECTED FRETTING-WEAR-RESISTANT COATINGS FOR TI-6-PERCENT-AL-4-PERCENT-V ALLOY
    BILL, RC
    [J]. WEAR, 1985, 106 (1-3) : 283 - 301