Retinal image quality after microincision intraocular lens implantation

被引:77
作者
Alió, JL
Schimchak, P
Montés-Micó, R
Galal, A
机构
[1] Miguel Hernandez Univ, Sch Med, VISSUM, Inst Oftalmol Alicante, Alicante 03016, Spain
[2] Res Inst Ophthalmol, Cairo, Egypt
关键词
D O I
10.1016/j.jcrs.2005.01.026
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
PURPOSE: To evaluate the modulation-transfer function (MTF) in eyes implanted with a conventional intraocular lens (IOL) and 2 IOLs designed for microincision cataract surgery (MICS). SETTING: Research, Development, and Innovation Department, Instituto Oftalmologico de Alicante, Alicante, Spain. METHODS: This prospective nonrandomized consecutive series comprised 30 eyes implanted with 1 of the following IOLs: conventional acrylic foldable (AcrySof MA60BM, Alcon Laboratories) or the UltraChoice 1.0 ThinOptX (ThinOptX Inc.) or the Acri.Smart 48S (Acri.Tech) MICS IOL. The 0.5 MTF and 0.1 MTF following MICS were calculated 3 months after implantation with the Optical Quality Analysis System (OQAS) for a 5 mm pupil. The differences were statistically analyzed with the Mann-Whitney U test. RESULTS: The values of 0.5 IVITF for AcrySof, UltraChoice, ThinOptX, and Acri.Smart IOLs were, respectively, 2.647 cycles per degree (cpd) +/- 0.833 (SD), 2.601 +/- 0.986 cpd, and 3.453 +/- 0.778 cpd. The mean 0.1 MTF values for the same IOLs were 8.720 +/- 3.074 cpd, 8.814 +/- 4.380 cpd, and 11.418 +/- 2.574 cpd, respectively. Statistical analysis did not show significant differences in 0.5 MTF and 0.1 MTF between the conventional IOL and MICS IOLs. CONCLUSIONS: Microincision cataract surgery IOLs showed excellent MTF performance when implanted after cataract surgery, equal to that of conventional IOLs. An in vivo MTF study may be an excellent option to evaluate IOL performance in the eye. (c) 2005 ASCRS and ESCRS.
引用
收藏
页码:1557 / 1560
页数:4
相关论文
共 9 条
[1]
Alio J. L., 2004, MICS MICROINCISION C, P1
[2]
Contributions of the cornea and the lens to the aberrations of the human eye [J].
Artal, P ;
Guirao, A .
OPTICS LETTERS, 1998, 23 (21) :1713-1715
[3]
THROUGH FOCUS IMAGE QUALITY OF EYES IMPLANTED WITH MONOFOCAL AND MULTIFOCAL INTRAOCULAR LENSES [J].
ARTAL, P ;
MARCOS, S ;
NAVARRO, R ;
MIRANDA, I ;
FERRO, M .
OPTICAL ENGINEERING, 1995, 34 (03) :772-779
[4]
Compensation of corneal aberrations by the internal optics in the human eye [J].
Artal, Pablo ;
Guirao, Antonio ;
Berrio, Esther ;
Williams, David R. .
JOURNAL OF VISION, 2001, 1 (01) :1-8
[5]
Presbyopia and the optical changes in the human crystalline lens with age [J].
Glasser, A ;
Campbell, MCW .
VISION RESEARCH, 1998, 38 (02) :209-229
[6]
Guirao A, 2002, ARCH OPHTHALMOL-CHIC, V120, P1143
[7]
MODULATION TRANSFER-FUNCTIONS OF EYES IMPLANTED WITH INTRAOCULAR LENSES [J].
NAVARRO, R ;
FERRO, M ;
ARTAL, P ;
MIRANDA, I .
APPLIED OPTICS, 1993, 32 (31) :6359-6367
[8]
PRATS JLR, 2004, MICS MICRO INCISION, P67
[9]
DETERMINATION OF THE POINT-SPREAD FUNCTION OF HUMAN EYES USING A HYBRID OPTICAL-DIGITAL METHOD [J].
SANTAMARIA, J ;
ARTAL, P ;
BESCOS, J .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (06) :1109-1114